Home › Power Source / Network › 1NZ-FE BATTERY / CHARGING › GENERATOR › 2011.08–2014.07
RM19S0E _57 Power Source / Network _051486 1NZ-FE BATTERY / CHARGING _0248281 GENERATOR G

1NZ-FE BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27370 1.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A153828E01
0.639,0.717 0.795,0.898 0.156,0.181 10 *a

Using a vernier caliper, measure the length of the exposed brushes.

Text in Illustration
*a Length

Standard exposed length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum exposed length:

4.5 mm (0.177 in.)


If the exposed length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 2.INSPECT GENERATOR ROTOR ASSEMBLY

A372528E02
1.885,1.031 2.333,0.531 2.333,0.531 2,1.083 false 2.385,0.354 2.698,0.552 0.313,0.198 10 false *1

a.

Check the generator rotor for open circuits.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.7 to 2.1 Ω


Text in Illustration
*1 Slip Ring

If the resistance is not as specified, replace the generator rotor assembly.



b.
A372529E02
1.281,0.958 0.573,0.635 false 2.198,1.302 2.531,0.625 false 0.323,0.479 0.635,0.677 0.313,0.198 10 false *2 2.552,0.427 2.865,0.625 0.313,0.198 10 false *1

Check the generator rotor for short circuits.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor Always 10 MΩ or higher


Text in Illustration
*1 Slip Ring
*2 Rotor

If the result is not as specified, replace the generator rotor assembly.



c.
A158899

Check that the generator rotor bearing is not rough or worn.

If necessary, replace the generator rotor assembly.


d.
A182587E03
0.552,0.615 0.771,0.802 0.219,0.188 10 false *a

Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.8 mm (0.559 to 0.567 in.)


Minimum diameter:

14.0 mm (0.551 in.)


Text in Illustration
*a Diameter

If the diameter is less than the minimum, replace the generator rotor assembly.


e.
A235337

Check that the slip rings are not rough or scored.

If rough or scored, replace the generator rotor assembly.


Hide 27310 3.INSPECT GENERATOR DRIVE END FRAME ASSEMBLY

A219757E01
2.868,0.061 3.025,0.211 0.158,0.15 10 *1

a.

Inspect the stator coil for open circuits.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Coil lead - Coil lead Always Below 1 Ω


Text in Illustration
*1 Ohmmeter

If the result is not as specified, replace the generator assembly.



b.
A219758E01
2.86,0.052 3.014,0.205 0.154,0.153 10 *1

Inspect the stator coil for ground.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Coil lead - Generator drive end frame assembly Always 10 kΩ or higher


Text in Illustration
*1 Ohmmeter

If the result is not as specified, replace the generator assembly.



c.
A153387

Inspect the generator drive end frame bearing.

i.

Check that the bearing is not rough or worn.

If necessary, replace the generator assembly.



Hide 27357 4.INSPECT GENERATOR HOLDER WITH RECTIFIER

A182588E11
0.938,1.771 0.688,1.771 false 1.865,2.813 1.865,2.167 true 1.385,2.302 1.865,2.177 true 1.854,2.177 2.208,2.292 true 1.813,1.979 1.969,2.156 0.156,0.177 10 false E 2.677,1.521 2.833,1.698 0.156,0.177 10 false E 2.604,0.115 2.76,0.292 0.156,0.177 10 false B 2.74,0.552 2.927,0.729 0.188,0.177 10 false P3 2.208,0.542 2.396,0.719 0.188,0.177 10 false P2 1.677,0.542 1.865,0.719 0.188,0.177 10 false P1 0.844,2.229 1.031,2.406 0.188,0.177 10 false P1 1.208,3 1.396,3.177 0.188,0.177 10 false P2 0.563,1.688 0.719,1.865 0.156,0.177 10 false B 2.656,2.385 2.844,2.563 0.188,0.177 10 false P3

a.

Check the resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
P1, P2, P3 and B Always Resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction.
P1, P2, P3 and E Always Resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction.


If the result is not as specified, replace the generator holder with rectifier.



Hide 27700A 5.INSPECT GENERATOR REGULATOR ASSEMBLY

a.

Check the resistance.

i.
A182589E04
1.396,1.76 1.531,1.969 false 1.833,1.24 0.865,0.573 true 0.74,0.469 0.854,0.625 0.115,0.156 10 false F 1.583,1.906 1.729,2.104 0.146,0.198 10 false B

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminals F - Terminals B Always When the positive and negative poles between terminals F and B are exchanged, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction.


If the result is not as specified, replace the generator regulator assembly.


ii.
A182590E04
1.156,0.74 0.885,0.333 false 1.885,1.344 1.583,1.938 true 1.521,1.958 1.635,2.115 0.115,0.156 10 false F 0.75,0.24 0.865,0.396 0.115,0.156 10 false E

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminals E - Terminals F Always When the positive and negative poles between terminals E and F are exchanged, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction.


If the result is not as specified, replace the generator regulator assembly.