27370
1.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
Using a vernier caliper, measure the length of the exposed brushes.
| *a | Length |
9.5 to 11.5 mm (0.374 to 0.453 in.)
4.5 mm (0.177 in.)
If the exposed length is less than the minimum, replace the generator brush holder assembly.
27330
2.INSPECT GENERATOR ROTOR ASSEMBLY
Check the generator rotor for open circuits.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Slip ring | 20°C (68°F) | 1.7 to 2.1 Ω |
| *1 | Slip Ring |
If the resistance is not as specified, replace the generator rotor assembly.
Check the generator rotor for short circuits.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Rotor | Always | 10 MΩ or higher |
| *1 | Slip Ring |
| *2 | Rotor |
If the result is not as specified, replace the generator rotor assembly.
Check that the generator rotor bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
Using a vernier caliper, measure the slip ring diameter.
14.2 to 14.8 mm (0.559 to 0.567 in.)
14.0 mm (0.551 in.)
| *a | Diameter |
If the diameter is less than the minimum, replace the generator rotor assembly.
Check that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor assembly.
27310
3.INSPECT GENERATOR DRIVE END FRAME ASSEMBLY
Inspect the stator coil for open circuits.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Coil lead - Coil lead | Always | Below 1 Ω |
| *1 | Ohmmeter |
If the result is not as specified, replace the generator assembly.
Inspect the stator coil for ground.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Coil lead - Generator drive end frame assembly | Always | 10 kΩ or higher |
| *1 | Ohmmeter |
If the result is not as specified, replace the generator assembly.
Inspect the generator drive end frame bearing.
Check that the bearing is not rough or worn.
If necessary, replace the generator assembly.
27357
4.INSPECT GENERATOR HOLDER WITH RECTIFIER
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| P1, P2, P3 and B | Always | Resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |
| P1, P2, P3 and E | Always | Resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |
If the result is not as specified, replace the generator holder with rectifier.
27700A
5.INSPECT GENERATOR REGULATOR ASSEMBLY
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminals F - Terminals B | Always | When the positive and negative poles between terminals F and B are exchanged, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |
If the result is not as specified, replace the generator regulator assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminals E - Terminals F | Always | When the positive and negative poles between terminals E and F are exchanged, there is a resistance of below 1 Ω in one direction but 10 kΩ or higher in the other direction. |
If the result is not as specified, replace the generator regulator assembly.