The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as the resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes. This sensor is used for frost prevention.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1413/13 | An open or short in the No. 1 cooler thermistor (evaporator temperature sensor) circuit. | ·
No. 1 cooler thermistor (evaporator temperature sensor) ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor /
Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F). |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
A
B
C
Check for DTCs (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DTC CHECK / CLEAR).
DTC B1413/13 is not output
OK
NG
Inspect the No. 1 cooler thermistor (evaporator temperature sensor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>INSPECTION).
OK
NG
Remove the air conditioning harness assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-2 - z4-6 (TEA) | Always | Below 1 Ω |
| A-1 - z4-5 (SGA) | Always | Below 1 Ω |
| A-2 - Body ground | Always | 10 kΩ or higher |
| A-1 - Body ground | Always | 10 kΩ or higher |
| *1 | Air Conditioning Harness Assembly |
OK
NG