Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)
RM19S0E _58 Vehicle Interior _051498 HEATING / AIR CONDITIONING _0248350 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  Blower Motor Circuit  


DESCRIPTION

The blower motor with fan sub-assembly operates according to signals from the air conditioning amplifier assembly. The blower motor with fan sub-assembly speed signals are transmitted by changes in the duty ratio.

WIRING DIAGRAM

E231124E02
3.833,0.802 4.625,0.979 0.792,0.177 10 false from Battery 2.99,0.969 3.302,1.125 0.313,0.156 10 false HTR 0.875,0.833 1.073,0.979 0.198,0.146 10 false +B 0.906,1.188 1.073,1.344 0.167,0.156 10 false SI 0.75,1.979 1.052,2.135 0.302,0.156 10 false GND 2.104,1.021 2.198,1.188 0.094,0.167 10 false 3 2.104,1.427 2.208,1.594 0.104,0.167 10 false 2 2.104,0.635 2.208,0.792 0.104,0.156 10 false 1 5.635,1.104 5.823,1.26 0.188,0.156 10 false 22 5.625,1.49 5.823,1.646 0.198,0.156 10 false 14 5.906,1.188 6.24,1.344 0.333,0.156 10 false BLW 5.896,1.594 6.229,1.74 0.333,0.146 10 false GND 0.219,2.385 0.469,2.563 0.25,0.177 10 false F97 0.208,2.573 1.052,2.906 0.844,0.333 10 false Blower Motor Control 5.677,2.042 5.958,2.198 0.281,0.156 10 false F42 5.656,2.198 6.875,2.563 1.219,0.365 10 false Air Conditioning Amplifier Assembly 1.135,1.094 1.229,1.26 0.094,0.167 10 false 3 1.135,1.49 1.24,1.656 0.104,0.167 10 false 2 1.135,0.729 1.24,0.885 0.104,0.156 10 false 1 2.094,1.813 2.188,1.979 0.094,0.167 10 false 6 2.083,2 2.208,2.156 0.125,0.156 10 false C 2.094,1.594 2.219,1.75 0.125,0.156 10 false C 2.094,1.219 2.219,1.375 0.125,0.156 10 false C 2.094,0.823 2.219,0.979 0.125,0.156 10 false C 1.135,1.875 1.229,2.042 0.094,0.167 10 false 6 0.833,1.583 1.073,1.74 0.24,0.156 10 false VM 1.156,2.396 1.969,2.969 0.813,0.573 10 false No. 1 Air Conditioning Wire 3.583,1.823 3.844,2 0.26,0.177 10 false F96 3.573,2 4.979,2.333 1.406,0.333 10 false Blower Motor with Fan Sub-Assembly 3.438,1.677 3.542,1.844 0.104,0.167 10 false 2 3.438,2 3.542,2.156 0.104,0.156 10 false 1 0.104,0.063 0.771,0.24 0.667,0.177 12 false for LHD:

E231125E01
3.566,0.799 4.353,0.975 0.788,0.177 10 from Battery 2.697,0.967 3.010,1.118 0.313,0.152 10 HTR 1.463,0.827 1.660,0.969 0.198,0.142 10 +B 1.491,1.212 1.661,1.370 0.170,0.158 10 SI 1.317,1.611 1.659,1.755 0.342,0.143 10 GND 1.744,0.715 1.872,0.884 0.128,0.170 10 3 1.744,1.093 1.845,1.263 0.100,0.170 10 2 1.744,1.499 1.852,1.655 0.107,0.156 10 1 5.32,1.1 5.504,1.256 0.184,0.156 10 22 5.31,1.499 5.504,1.659 0.194,0.160 10 14 5.597,1.213 5.934,1.369 0.336,0.156 10 BLW 5.597,1.618 5.930,1.764 0.333,0.145 10 GND 0.637,1.968 0.943,2.107 0.305,0.139 10 F36 0.637,2.123 1.884,2.456 1.246,0.333 10 Blower Motor with Fan Sub-Assembly 5.348,1.965 5.629,2.121 0.281,0.156 10 F42 5.348,2.126 6.574,2.445 1.225,0.319 10 Air Conditioning Amplifier Assembly 0.123,0.056 0.799,0.233 0.677,0.177 12 for RHD:

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Active Test.


e.

According to the display on the intelligent tester, perform the Active Test.

Air Conditioner
Tester Display Test Part Control Range Diagnostic Note
Blower Motor Blower motor Min.: 0, Max.: 31 -

OK:

Blower motor with fan sub-assembly operates and blower motor speed changes.


Result
Result Proceed to
OK A
NG (Blower motor with fan sub-assembly does not operate)*1 B
NG (Blower motor with fan sub-assembly operates but blower motor speed does not change)*1 C
NG (Blower motor with fan sub-assembly operates or blower motor speed changes)*2 D

*1: for LHD

*2: for RHD




A

B

2.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

C

7.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

D

9.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BATTERY AND BODY GROUND)
2.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY
a.

Inspect the blower motor with fan sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>INSPECTION).



OK

3.CHECK HARNESS AND CONNECTOR (NO. 1 AIR CONDITIONING WIRE - BATTERY AND BODY GROUND)

NG

3.CHECK HARNESS AND CONNECTOR (NO. 1 AIR CONDITIONING WIRE - BATTERY AND BODY GROUND)
a.
U158665E02
0.115,0.125 0.281,0.281 0.167,0.156 10 false *a 0.604,0.948 0.76,1.125 0.156,0.177 10 false C

Disconnect the C No. 1 air conditioning wire connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C-1 - Body ground Always 11 to 14 V



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C-6 - Body ground Always Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to No. 1 Air Conditioning Wire)



OK

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING WIRE BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING WIRE BODY GROUND)
a.

Disconnect the F42 air conditioning amplifier assembly connector.


b.

Disconnect the C No. 1 air conditioning wire connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F42-22 (BLW) - C-3 Always Below 1 Ω
F42-14 (GND) - Body ground Always Below 1 Ω
F42-22 (BLW) - Body ground Always 10 kΩ or higher




OK

5.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - NO. 1 AIR CONDITIONING WIRE AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - NO. 1 AIR CONDITIONING WIRE AND BODY GROUND)
a.

Disconnect the F96 blower motor with fan sub-assembly connector.


b.

Disconnect the C No. 1 air conditioning wire connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F96-2 - C-2 Always Below 1 Ω
F96-1 - Body ground Always Below 1 Ω
F96-2 - Body ground Always 10 kΩ or higher




OK

6.INSPECT NO. 1 AIR CONDITIONING WIRE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.INSPECT NO. 1 AIR CONDITIONING WIRE
a.

Remove the No. 1 air conditioning wire.


b.
U158666E01
0.703,1.199 0.859,1.381 0.156,0.181 10 C 0.083,0.092 0.253,0.252 0.170,0.161 10 *1 0.575,3.184 0.832,3.366 0.256,0.181 10 F97 0.92,2.825 1.115,2.972 0.195,0.147 10 +B 2.317,2.825 2.543,2.972 0.225,0.147 10 VM 0.974,3.993 1.125,4.139 0.151,0.147 10 SI 2.317,3.993 2.652,4.139 0.334,0.147 10 GND 1.435,3.32 1.172,2.901 false 2.017,3.32 2.28,2.901 false 1.978,3.663 2.242,4.081 false 1.198,4.081 1.462,3.663 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C-1 - F97-1 (+B) Always Below 1 Ω
C-2 - F97-2 (VM) Always Below 1 Ω
C-3 - F97-3 (SI) Always Below 1 Ω
C-6 - F97-6 (GND) Always Below 1 Ω
C-1 - Body ground Always 10 kΩ or higher
C-2 - Body ground Always 10 kΩ or higher
C-3 - Body ground Always 10 kΩ or higher
C-6 - Body ground Always 10 kΩ or higher


Text in Illustration
*1 No. 1 Air Conditioning Wire



OK

7.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPLACE NO. 1 AIR CONDITIONING WIRE

7.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
a.
U158598E01
1.568,0.385 1.824,0.567 0.256,0.181 10 F42 0.076,0.055 0.246,0.216 0.170,0.161 10 *a 2.302,2.2 2.628,2.363 0.326,0.163 10 BLW 0.434,2.207 0.771,2.359 0.336,0.152 10 GND 2.852,3.977 3.195,4.123 0.343,0.145 10 GND 1.05,1.261 0.849,2.284 false 2.081,1.356 2.265,2.287 false

Remove the air conditioning amplifier assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).


b.

Remove the No. 1 air conditioning wire.


c.

Reconnect the air conditioning amplifier assembly connector.


d.

Reconnect the blower motor with fan sub-assembly connector.


e.

Using an oscilloscope, check the waveform.

Measurement Condition
Item Content
Terminal No. (Symbol) F42-22 (BLW) - F42-14 (GND)
Tester Range 1 V/DIV., 500 μs/DIV.
Condition Ignition switch ON
Blower switch LO

OK:

Waveform is as shown in the illustration.


HINT:

Waveform varies with the blower level.


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)



OK

8.REPLACE BLOWER MOTOR CONTROL

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

8.REPLACE BLOWER MOTOR CONTROL
a.

Replace the blower motor control with a new or normally functioning one (See page Vehicle Interior>HEATING / AIR CONDITIONING>BLOWER MOTOR CONTROLLER>REMOVAL).


b.

Operate the blower motor with fan sub-assembly to check that it functions properly.

OK:

Blower motor with fan sub-assembly operates normally.




OK

END (BLOWER MOTOR CONTROL IS FAULTY)

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

9.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BATTERY AND BODY GROUND)
a.
U158597E01
0.53,0.931 0.786,1.112 0.256,0.181 10 F36 0.077,0.07 0.247,0.230 0.170,0.161 10 *a 0.748,1.628 1.074,1.773 0.326,0.145 10 GND 2.35,1.623 2.555,1.776 0.205,0.152 10 +B 1.418,1.329 1.16,1.703 false 2.06,1.33 2.317,1.704 false

Disconnect the F36 blower motor with fan sub-assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
F36-3 (+B) - Body ground Always 11 to 14 V



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F36-1 (GND) - Body ground Always Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Blower Motor with Fan Sub-Assembly)



OK

10.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BODY GROUND)
a.

Disconnect the F42 air conditioning amplifier assembly connector.


b.

Disconnect the F36 blower motor with fan sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F42-22 (BLW) - F36-2 (SI) Always Below 1 Ω
F42-14 (GND) - Body ground Always Below 1 Ω
F42-22 (BLW) - Body ground Always 10 kΩ or higher




OK

11.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)
a.
U158598E01
1.568,0.385 1.824,0.567 0.256,0.181 10 F42 0.076,0.055 0.246,0.216 0.170,0.161 10 *a 2.302,2.2 2.628,2.363 0.326,0.163 10 BLW 0.434,2.207 0.771,2.359 0.336,0.152 10 GND 2.852,3.977 3.195,4.123 0.343,0.145 10 GND 1.05,1.261 0.849,2.284 false 2.081,1.356 2.265,2.287 false

Remove the air conditioning amplifier assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).


b.

Reconnect the air conditioning amplifier assembly connector.


c.

Reconnect the blower motor with fan sub-assembly connector.


d.

Using an oscilloscope, check the waveform.

Measurement Condition
Item Content
Terminal No. (Symbol) F42-22 (BLW) - F42-14 (GND)
Tester Range 1 V/DIV., 500 μs/DIV.
Condition Ignition switch ON
Blower switch LO

OK:

Waveform is as shown in the illustration.


HINT:

Waveform varies with the blower level.


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)



OK

12.REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

12.REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY
a.

Replace the blower motor with fan sub-assembly with a new or normally functioning one (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>REMOVAL).


b.

Operate the blower motor with fan sub-assembly to check that it functions properly.

OK:

Blower motor with fan sub-assembly operates normally.




OK

END (BLOWER MOTOR WITH FAN SUB-ASSEMBLY IS FAULTY)

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY