Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)
RM19S0E _58 Vehicle Interior _051498 HEATING / AIR CONDITIONING _0248350 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) D

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  SYSTEM DESCRIPTION  


GENERAL


a.

The air conditioning system has the following features:

·

In accordance with the temperature set using the temperature control switch, the air conditioning amplifier determines the outlet temperature based on the input signals from various sensors. In addition, corrections are added in accordance with the signals from the water temperature sensor to control the outlet air temperature.

·

Controls the blower motor in accordance with the airflow volume determined by the air conditioning amplifier based on the input signals from various sensors.

·

Automatically changes the outlets in accordance with the outlet mode ratio that is determined by the air conditioning amplifier based on the input signals from various sensors.

·

Checks the sensors in accordance with the operations of the air conditioner switches.

·

The air conditioning amplifier has the function of controlling the indicator lighting.




MODE POSITION AND DAMPER OPERATION


a.

Mode position and damper operation

U158671E01
4.731,1.024 4.906,1.200 0.175,0.176 10 *4 0.438,0.998 0.675,1.191 0.236,0.193 10 *a 2.059,1.165 2.329,1.358 0.270,0.194 10 *b 1.2,3.372 1.376,3.518 0.175,0.146 10 *1 3.269,3.874 3.456,4.038 0.187,0.164 10 *6 2.513,3.441 2.702,3.593 0.189,0.152 10 *3 2.693,0.826 2.870,0.981 0.177,0.155 10 *2 4.327,3.945 4.516,4.108 0.189,0.163 10 *5 5.415,3.874 5.599,4.038 0.184,0.164 10 *6 6.306,1.592 6.507,1.756 0.201,0.164 10 *7 5.805,2.069 6.276,1.709 false 6.276,1.709 5.786,2.75 false 1.378,3.031 1.303,3.333 false 2.668,3.126 2.593,3.428 false 2.88,0.886 3.27,1.968 false

Text in Illustration
*1 Blower Motor with Fan Sub-Assembly *2 Heater Radiator Unit Sub-Assembly
*3 No. 1 Cooler Evaporator Sub-Assembly *4 Front Defroster
*5 Center Register *6 Side Register
*7 Front Footwell Register Duct - -
*a Fresh Air *b Recirculated Air

HINT:

This Illustration is damper operation image. The number and location of the dampers is different to the actual unit.


Functions of Main Dampers
Control Damper Control Position Damper Position Operation
Air Inlet Control Damper FRESH A Allows outside air to enter.
RECIRC B Recirculates internal air.
Air Mix Control Damper MAX COLD to MAX HOT Temperature Setting C, D Continuously changes mix ratio of warm and cool air between COOL and HOT.
Mode Control Damper FACE
E264852

M, L, E, J Blows air from center register and side registers.
BI - LEVEL
E264849

N, R, F, J Blows air from center register, side registers and front footwell register.
FOOT
E264850

O, K, F, I Blows air from side registers and front footwell register. Also, blows some air from front defroster.
FOOT / DEF
E264851

O, K, G, H Blows air from front defroster, side registers and front footwell register.
DEF
E264847

O, R, E, Q Blows air from front defroster and side register.



AIR OUTLET AND AIRFLOW VOLUME


E232454E02
2.844,1.75 2.958,1.906 0.115,0.156 10 false A 4.448,1.719 4.573,1.875 0.125,0.156 10 false B 1.49,2.302 1.615,2.458 0.125,0.156 10 false B 1.792,3.188 1.917,3.344 0.125,0.156 10 false C 3.385,2.74 3.51,2.896 0.125,0.156 10 false C 2.031,0.469 2.156,0.625 0.125,0.156 10 false D 0.448,2.198 0.573,2.354 0.125,0.156 10 false F 4.313,1.406 4.438,1.563 0.125,0.156 10 false E 1.323,1.948 1.448,2.104 0.125,0.156 10 true E 4.49,1.104 4.615,1.26 0.125,0.156 10 false F

Air Outlet Mode Air Outlet Position Symbol
A B C D E F
Center Face Side Face Foot Defroster Side Defroster Side Defroster
E264852

FACE
E331836

E331836

- - - -
E264850

BI - LEVEL
E331837

E331837

E331837

- - -
E264850

FOOT -
E331837

E331836

E331839

E331839

E331839

E264851

FOOT/DEF -
E346355

E331837

E331837

E331839

E331839

E264847

DEF -
E346355

-
E331836

E331839

E331839


The size of the circle ○ indicates the proportion of airflow volume.