DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temp Sensor | Ambient temperature sensor /
Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature is displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor /
Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F). |
| Evaporator Target Temp | Target evaporator temperature /
Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Target evaporator temperature displayed | - |
| Engine Coolant Temp | Engine coolant temperature /
Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature is displayed after engine warmed up | - |
| Regulator Pressure Sensor | Regulator pressure sensor /
Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual regulator pressure is displayed | - |
| Regulator Control Current | Regulator control current /
Min.: 0 A Max.: 0.997 A |
Value changes between 0.12 A and 0.997 A in accordance with compressor operation | - |
| Refrigerant Shortage Check | Refrigerant shortage check function /
ON or OFF |
Customized value displayed | - |
| A/C Cutoff Signal | A/C control cutoff signal /
ON or OFF |
- | - |
| Refrigerant Gas Type | Refrigerant gas type /
R134a or 1234yf |
Refrigerant gas type displayed | - |
| Number of Trouble Codes | Number of trouble codes /
Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Magnetic Clutch Relay | A/C Compressor | OFF or ON | - |