Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR
RM19S0E _58 Vehicle Interior _051498 HEATING / AIR CONDITIONING _0248361 ROOM TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  ROOM TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625Q 1.INSPECT ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)

a.

Measure the resistance according to the value(s) in the table below.

E346198E01
1.875,1.542 2.333,1.813 false 4.521,1.719 4.823,1.448 false 1.771,1.552 1.313,1.823 false 0.365,0.313 0.583,0.51 0.219,0.198 10 false *a 1.104,1.771 1.281,1.958 0.177,0.188 10 false *2 2.396,1.76 2.615,1.958 0.219,0.198 10 false *1 3.688,0.354 3.906,0.552 0.219,0.198 10 false *c 3.667,2.667 3.885,2.865 0.219,0.198 10 false 0.0 3.656,2.417 3.875,2.615 0.219,0.198 10 false 0.5 3.656,2.198 3.875,2.396 0.219,0.198 10 false 1.0 3.656,1.958 3.875,2.156 0.219,0.198 10 false 1.5 3.656,1.75 3.875,1.948 0.219,0.198 10 false 2.0 3.656,1.542 3.875,1.74 0.219,0.198 10 false 2.5 3.656,1.313 3.875,1.51 0.219,0.198 10 false 3.0 3.667,1.083 3.885,1.281 0.219,0.198 10 false 3.5 3.667,0.854 3.885,1.052 0.219,0.198 10 false 4.0 3.958,2.802 4.177,3 0.219,0.198 10 false 10 4.813,2.813 5.031,3.01 0.219,0.198 10 false 30 4.396,2.813 4.615,3.01 0.219,0.198 10 false 20 5.271,2.802 5.49,3 0.219,0.198 10 false 40 5.719,2.802 5.938,3 0.219,0.198 10 false 50 6.198,2.813 6.417,3.01 0.219,0.198 10 false 60 3.927,2.958 4.188,3.146 0.26,0.188 10 false (50) 4.344,2.969 4.604,3.156 0.26,0.188 10 false (68) 4.781,2.979 5.042,3.167 0.26,0.188 10 false (86) 5.208,2.979 5.531,3.167 0.323,0.188 10 false (104) 5.646,2.979 5.969,3.167 0.323,0.188 10 false (122) 6.125,2.979 6.448,3.167 0.323,0.188 10 false (140) 6.271,3.229 6.49,3.427 0.219,0.198 10 false *d 4.885,1.313 5.104,1.51 0.219,0.198 10 false *b

Text in Illustration
*a Component without harness connected
(Room Temperature Sensor)
*b Acceptable Range
*c Resistance (kΩ)
*d Temperature (°C (°F))

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the sensor connector.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


If the result is not as specified, replace the room temperature sensor.