Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM › from 2014.07
RM19S0E _59 Vehicle Exterior _051505 LIGHTING (EXT) _0248415 LIGHTING SYSTEM U

LIGHTING (EXT)  LIGHTING SYSTEM  FAIL-SAFE CHART  


LED HEADLIGHT SYSTEM


The light control LED ECU operates in fail-safe mode if an abnormal condition such as those listed below has been detected.

Item Abnormality Detection Condition Return Condition Multi-information Display
Abnormal input voltage
(High input voltage)
Abnormal power source voltage (more than 17 V) is detected. Normal power source voltage (10 to 16 V) is detected. "Check Headlight System" message is displayed
Abnormal input voltage
(Low input voltage)*1
If the power source voltage is too low (8.5 to 10 V), LED output current will be limited. (Headlights will remain illuminated.) Output current limit is canceled when the voltage returns to the specified operating voltage (10 to 16 V). "Check Headlight System" message is displayed
If the power source voltage is too low (below 6 V), headlight operation will stop. If the voltage returns to 8.5 V or more, headlight operation will resume.
Abnormal output
·

Open in output side circuit

·

Short between output terminal and body ground

·

Short between output terminals (Hi and Lo)


Light control switch is turned from off to head position. "Check Headlight System" message is displayed

*1: When the headlights are on and the input voltage is between 6 and 10 V, the headlights dim.