LED HEADLIGHT SYSTEM
The light control LED ECU operates in fail-safe mode if an abnormal condition such as those listed below has been detected.
| Item | Abnormality Detection Condition | Return Condition | Multi-information Display |
|---|---|---|---|
| Abnormal input voltage
(High input voltage) |
Abnormal power source voltage (more than 17 V) is detected. | Normal power source voltage (10 to 16 V) is detected. | "Check Headlight System" message is displayed |
| Abnormal input voltage
(Low input voltage)*1 |
If the power source voltage is too low (8.5 to 10 V), LED output current will be limited. (Headlights will remain illuminated.) | Output current limit is canceled when the voltage returns to the specified operating voltage (10 to 16 V). | "Check Headlight System" message is displayed |
| If the power source voltage is too low (below 6 V), headlight operation will stop. | If the voltage returns to 8.5 V or more, headlight operation will resume. | ||
| Abnormal output | ·
Open in output side circuit ·
Short between output terminal and body ground ·
Short between output terminals (Hi and Lo) |
Light control switch is turned from off to head position. | "Check Headlight System" message is displayed |
*1: When the headlights are on and the input voltage is between 6 and 10 V, the headlights dim.