89120A
1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
Disconnect the automatic light control sensor connector.
Measure the voltage according to the value(s) in the table below.
| *a | Front view of wire harness connected
(to Automatic Light Control Sensor) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 (CLTB) - 5 (CLTE) | Ignition switch off | Below 1 V |
| Ignition switch on | 11 to 14 V |
If the result is not as specified, repair or replace the wire harness or connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (CLTE) -Body ground | Always | Below 1 Ω |
If the result is not as specified, repair or replace the wire harness or connector.
Reconnect the automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
| *a | Rear view of wire harness connector
(to Automatic Light Control Sensor) |
Check the waveform.
| Tester Connection | Tool Setting | Condition | Specified Condition |
|---|---|---|---|
| 4 (CLTS) - 5 (CLTE) | 5 V/DIV., 5 ms./DIV | Ignition switch ON, light control switch in AUTO | Correct waveform is as shown |
If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, replace the automatic light control sensor.