Home › Vehicle Interior › PRE-CRASH SAFETY › PRE-CRASH SAFETY SYSTEM › from 2018.06
RM19S0E _58 Vehicle Interior _063185 PRE-CRASH SAFETY _0307822 PRE-CRASH SAFETY SYSTEM U

PRE-CRASH SAFETY  PRE-CRASH SAFETY SYSTEM  TERMINALS OF ECU  


CHECK PRE-CRASH SAFETY CITY SENSOR


E256359E81
2.083,0.833 2.583,1.083 0.5,0.25 2.208,0.875 2.667,1.073 0.458,0.198 10 false L11

a.

Disconnect the L11 pre-crash safety city sensor connector.

NOTICE:
·

DTCs may be output when connectors are disconnected during inspection. Therefore, be sure to clear the DTCs using the GTS once the inspection has been completed.

·

If a load of more than 10 kg (22 lb) is placed on the connector, it may break. Do not place more load than is necessary on the connector.




b.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
L11-9 (PCSW) - Body ground V - Body ground Pre-crash safety system cancel switch assembly signal Pre-crash safety system cancel switch assembly on Below 1 Ω
Pre-crash safety system cancel switch assembly off 100 kΩ or higher
L11-7 (IG1) - Body ground G - Body ground Power source Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
L11-10 (GND) - Body ground W-B - Body ground Ground Always Below 1 Ω

HINT:

If the result is not as specified, there may be a malfunction on the wire harness side.



c.

Reconnect the L11 pre-crash safety city sensor connector.


d.

Measure the voltage according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
L11-8 (BUZ) - Body ground P - Body ground Pre-crash safety city heater operation signal Ignition switch ON
Pre-crash safety city heater not operating
11 to 14 V
Ignition switch ON
Pre-crash safety city heater operating
0 to 1.5 V
L11-1 (SPR) - Body ground GR - Body ground Pre-crash safety city heater drive signal Ignition switch ON
Pre-crash safety city heater not operating
11 to 14 V
Ignition switch ON
Pre-crash safety city heater operating
0 to 1.5 V


e.

Check for pulses according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
L11-5 (CA1P) - Body ground LG - Body ground CAN communication signal Ignition switch ON Pulse generation
(See waveform 1)
L11-11 (CA1N) - Body ground W - Body ground CAN communication signal Ignition switch ON Pulse generation
(See waveform 1)


f.
E318038E04
0.406,0.656 0.865,0.854 0.458,0.198 10 false CH1 0.406,1.24 0.865,1.438 0.458,0.198 10 false CH2 2.938,1.208 3.396,1.406 0.458,0.198 10 false GND 2.938,1.583 3.396,1.781 0.458,0.198 10 false GND

Waveform 1

i.

CAN communication signal

Item Content
Tester Connection
·

CH1: L11-5 (CA1P) - Body ground

·

CH2: L11-11 (CA1N) - Body ground


Tool Setting 1 V/DIV., 50 μsec./DIV.
Condition Ignition switch ON

HINT:

If the result is not as specified, there is a CAN bus line, terminating resistor circuit (or product with this circuit) or pre-crash safety city sensor malfunction.