Home › Drivetrain · U340E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM (for Sedan)

DTC    P0710    Transmission Fluid Temperature Sensor "A" Circuit

DTC    P0712    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713    Transmission Fluid Temperature Sensor "A" Circuit High Input


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input to the ECM.
The sensor resistance changes with the transmission fluid temperature. As the temperature rises, the sensor resistance decreases. The ECM applies a voltage to the temperature sensor through ECM terminal THO1, and the ECM calculates the fluid temperature based on the voltage signal.

HINT:
  1. The ATF temperature is likely to increase under conditions such as towing, climbing hills and in heavy traffic.
  2. When the ATF temperature sensor is normal, the transmission locks up in 4th gear with the shift lever in D and in 3rd gear with the shift lever in 3rd.


DTC No.
DTC Detection Condition
Trouble Area
P0710
Both (a) and (b) are detected momentarily within 0.5 seconds when neither P0712 nor P0713 is detected (1-trip detection logic).
(a) ATF temperature sensor resistance is less than 79 Ω.
(b) ATF temperature sensor resistance is more than 156 kΩ.

HINT:
Within 0.5 seconds, malfunction switches from (a) to (b) or from (b) to (a).

  1. Wire harness or connector
  2. Transmission wire (ATF temperature sensor)
  3. ECM
P0712
ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic).
  1. Wire harness or connector
  2. Transmission wire (ATF temperature sensor)
  3. ECM
P0713
ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more and either of the following conditions is met (1-trip detection logic):
  1. Wire harness or connector
  2. Transmission wire (ATF temperature sensor)
  3. ECM
(A) 10 minutes or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
(B) 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (-20.875°F).

MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects opens or shorts in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM turns on the MIL and stores the DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on the Techstream display.


WIRING DIAGRAM


C161969E14


INSPECTION PROCEDURE


DATA LIST

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the Techstream to the DLC3.

  4. Turn the ignition switch to ON.

  5. Turn the Techstream on.

  6. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data.

  7. In accordance with the display on the Techstream, read the Data List.

    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    A/T Oil Temperature 1
    ATF Temperature Sensor Value/
    min.: -40°C (-40°F)
    max.: 215°C (419°F)
    1. After Stall Test; Approximately 80°C (176°F)
    2. Equal to ambient temperature when cold soak
    If value is -40°C (-40°F) or 150°C (302°F) or more, ATF temperature sensor circuit is open or short.

    HINT:
    When DTC P0712 is output and the Techstream reading is 150°C (302°F) or more, there is a short circuit.
    When DTC P0713 is output and the Techstream reading is -40°C (-40°F), there is an open circuit.
    Measure the resistance between terminal THO1 and the body ground.

    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or more
    Short circuit

    HINT:
    If a circuit related to the ATF (Automatic Transmission Fluid) temperature sensor becomes open, P0713 is immediately set (within 0.5 seconds).

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)
C229166E19
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (THO) - 6 (E2)
    Always
    79 Ω to 156 kΩ
    1 (THO) - Body ground
    Always
    10 kΩ or higher
    6 (E2) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)

    HINT:
    If the resistance is outside the specified range at either of the ATF temperatures shown in the table below, the driveability of the vehicle may be affected.

    Standard Resistance:
    ATF Temperature
    Specified Condition
    10°C (50°F)
    5 to 8 kΩ
    25°C (77°F)
    2.5 to 4.5 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ



NG
REPAIR OR REPLACE TRANSMISSION WIRE (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
C229165E22
  1. Connect the transmission wire connector to the transaxle.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C20-72 (THO1) - C20-95 (ETHO)
    Always
    79 Ω to 156 kΩ
    C20-72 (THO1) - Body ground
    Always
    10 kΩ or higher
    C20-95 (ETHO) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)