Home › Drivetrain · U340E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM (for Hatchback)

DTC    P0973    Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)

DTC    P0974    Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)


DESCRIPTION

Shifting from 1st to 4th is performed in combination with the ON and OFF operations of shift solenoid valves S1 and S2 which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be driven smoothly.
(If an open or short circuit occurs, the ECM stops sending current to the affected circuit.)
Fail-safe function (Click here).

DTC No.
DTC Detection Condition
Trouble Area
P0973
ECM detects short in solenoid valve S1 circuit 4 times when solenoid valve S1 is operated (1 trip detection logic).
  1. Wire harness or connector
  2. Transmission wire
  3. Shift solenoid valve S1
  4. ECM
P0974
ECM detects open in solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated (1 trip detection logic).
  1. Wire harness or connector
  2. Transmission wire
  3. Shift solenoid valve S1
  4. ECM

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in the shift solenoid valve S1 circuit, the ECM detects the problem and the MIL comes on. Illuminating the MIL, the ECM performs the fail-safe and turns the other functioning shift solenoid valve ON/OFF.
(If an open or short circuit occurs, the ECM stops sending current to the affected circuit.)

MONITOR STRATEGY


Related DTCs
P0973: Shift solenoid valve S1/Range check
P0974: Shift solenoid valve S1/Range check
Required sensors/Components
Shift solenoid valve S1
Frequency of operation
Continuous
Duration
0.128 seconds or more
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


P0973: Range check 
The monitor runs whenever the following DTCs are not present.
None
Solenoid
ON
Time after solenoid OFF to ON
0.008 seconds or more

P0974: Range check 
The monitor runs whenever the following DTCs are not present.
None
Solenoid
OFF
Time after solenoid ON to OFF
0.008 seconds or more

TYPICAL MALFUNCTION THRESHOLDS


P0973: Range check 
Shift solenoid valve S1 resistance
8 Ω or less

P0974: Range check 
Shift solenoid valve S1 resistance
100 kΩ or more

COMPONENT OPERATING RANGE


Shift solenoid valve S1 resistance
11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM


C243326E06


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).


HINT:
The shift solenoid valve S1 is turned on/off normally when the shift lever is in D:

Gearshift controlled by ECM
1st
2nd
3rd
4th
Shift solenoid valve S1
ON
ON
OFF
OFF

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1)
C229166E12
  1. Disconnect the C68 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    5 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
C233488E09
  1. Connect the C68 transmission wire connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C51-70 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE S1
C130146E14
  1. Remove the shift solenoid valve S1.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - Solenoid Body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.

    OK:
    The solenoid makes operating sounds.

    Text in Illustration 
    *a
    Component without harness connected
    (Shift Solenoid Valve S1)



NG
REPLACE SHIFT SOLENOID VALVE S1 (Click here)
OK

REPLACE TRANSMISSION WIRE (Click here)