DTC P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2) |
DTC P0977 Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0976 | ECM detects short in solenoid valve S2 circuit 4 times when solenoid valve S2 is operated (1 trip detection logic). |
|
| P0977 | ECM detects open in solenoid valve S2 circuit 4 times when solenoid valve S2 is not operated (1 trip detection logic). |
|
| Related DTCs | P0976: Shift solenoid valve S2/Range check P0977: Shift solenoid valve S2/Range check |
| Required sensors/Components | Shift solenoid valve S2 |
| Frequency of operation | Continuous |
| Duration | 0.128 seconds or more |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor runs whenever the following DTCs are not present. | None |
| Solenoid | ON |
| Time after solenoid OFF to ON | 0.008 seconds or more |
| The monitor runs whenever the following DTCs are not present. | None |
| Solenoid | OFF |
| Time after solenoid ON to OFF | 0.008 seconds or more |
| Shift solenoid valve S2 resistance | 8 Ω or less |
| Shift solenoid valve S2 resistance | 100 kΩ or more |
| Shift solenoid valve S2 resistance | 11 to 15 Ω at 20°C (68°F) |

| Gearshift controlled by ECM | 1st | 2nd | 3rd | 4th |
| Shift solenoid valve S2 | ON | OFF | OFF | ON |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2) |
![]() |
Disconnect the C68 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 10 (S2) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the C68 transmission connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C51-69 (S2) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| *a | Front view of wire harness connector (to ECM) |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Remove the shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - Solenoid Body | 20°C (68°F) | 11 to 15 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.
| *a | Component without harness connected (Shift Solenoid Valve S2) |
|
| ||||
| OK | ||
| ||