Home › Engine / Hybrid System › 1NZ-FE ENGINE CONTROL › SFI SYSTEM (for Hatchback)

SFI SYSTEM (for Hatchback) > MIL Circuit


DESCRIPTION

The MIL (Malfunction Indicator Lamp) is used to indicate vehicle malfunctions detected by the ECM. When the ignition switch is turned to ON, power is supplied to the MIL circuit, and the ECM provides the circuit ground which illuminates the MIL.
The MIL operation can be checked visually: When the ignition switch is turned to ON, the MIL should be illuminated and should turn off after engine is started. If the MIL remains illuminated or is not illuminated, conduct the following troubleshooting procedure using the Techstream.

WIRING DIAGRAM


A257631E03


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK THAT MIL IS ILLUMINATED
  1. Perform troubleshooting in accordance with the table below.
    Result 
    Result
    Proceed to
    MIL remains ON
    A
    MIL does not illuminate
    B



B
Go to step 5
A


2.CHECK WHETHER MIL TURNS OFF
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Check if any DTCs have been detected. Note down any DTCs.
    Result 
    Result
    Proceed to
    No DTC detected
    A
    Any DTCs detected
    B

    HINT:
    Check for detected DTCs output from other ECUs which relate to the MIL.



B
REPAIR CIRCUITS INDICATED BY OUTPUT DTCS
A


3.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)
A246776E02
  1. Disconnect the ECM connector.

  1. Turn the ignition switch to ON.

  1. Check that the MIL is not illuminated.

    OK:
    MIL is not illuminated.

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)



NG
Go to step 4
OK

REPLACE ECM (Click here)  

4.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - ECM)
  1. Disconnect the combination meter assembly connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    A72-27 (W) or D100-11 (CHK) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

INSPECT COMBINATION METER ASSEMBLY (Click here)  

5.CHECK THAT MIL IS ILLUMINATED
  1. Check if the MIL is illuminated when the ignition switch is turned to ON.

    OK:
    MIL should be illuminated.



NG
Go to step 6
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)  

6.CHECK THAT ENGINE STARTS
  1. Turn the ignition switch to ON.

  1. Start the engine.
    Result 
    Result
    Proceed to
    Engine starts
    A
    Engine does not start*
    B

    HINT:
    *: The Techstream cannot communicate with the ECM.



B
GO TO VC OUTPUT CIRCUIT (Click here)
A


7.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - ECM)
  1. Disconnect the combination meter assembly connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    A72-27 (W) - D100-11 (CHK)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

INSPECT COMBINATION METER ASSEMBLY (Click here)