DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P2716 | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detecting logic). |
|

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (SLT+) - 8 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 3 (SLT+) - Body ground | Always | 10 kΩ or higher |
| 8 (SLT-) - Body ground | Always | 10 kΩ or higher |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C20-76 (SLT+) - C20-75 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| C20-76 (SLT+) - Body ground | Always | 10 kΩ or higher |
| C20-75 (SLT-) - Body ground | Always | 10 kΩ or higher |
| *a | Front view of wire harness connector (to ECM) |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
|
| ||||
| OK | ||
| ||