DTC B1413/13 Evaporator Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1413/13 | Open or short in evaporator temperature sensor circuit |
|

| 1.READ VALUE USING TECHSTREAM (EVAPORATOR FIN THERMISTOR) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Select the following menus: Body Electrical / Air Conditioner / Data List / Evaporator Fin Thermistor
According to the display on tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Evaporator fin thermistor | Evaporator fin thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.019°F) | Actual evaporator temperature is displayed | Open circuit: -29.7°C (-21.46°F) Short circuit: 59.55°C (139.019°F) |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) |
![]() |
Remove the evaporator temperature sensor.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| 1 - 2 | -5°C (23°F) | 5.65 to 6.95 kΩ |
| 1 - 2 | 0°C (32°F) | 4.40 to 5.35 kΩ |
| 1 - 2 | 5°C (41°F) | 3.40 to 4.15 kΩ |
| 1 - 2 | 10°C (50°F) | 2.70 to 3.25 kΩ |
| 1 - 2 | 15°C (59°F) | 2.14 to 2.58 kΩ |
| 1 - 2 | 20°C (68°F) | 1.71 to 2.05 kΩ |
| 1 - 2 | 25°C (77°F) | 1.38 to 1.64 kΩ |
| 1 - 2 | 30°C (86°F) | 1.11 to 1.32 kΩ |
Reinstall the evaporator temperature sensor.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (No. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the E2 No. 1 cooler thermistor (evaporator temperature sensor) connector.
Disconnect the E8 air conditioning amplifier connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| E2-2 - E8-10 (TE) | Below 1 Ω |
| E2-1 - E8-4 (SG-2) | Below 1 Ω |
| E2-2 - Body ground | 10 kΩ or higher |
| E2-1 - Body ground | 10 kΩ or higher |
Reconnect the No. 1 cooler thermistor connector.
Reconnect the air conditioning amplifier connector.
|
| ||||
| OK | ||
| ||