DTC P060E Internal Control Module Throttle Position Performance |
| DTC No. | DTC Detection Condition | Trouble Area |
| P060E | Either condition is met (1 trip detection logic):
| ECM |
| Related DTCs | P060E: Internal Control Module, Throttle Position |
| Required Sensors/Components (Main) | ECM |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 1 second: Case 1 13 times: Case 2 |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs not present | None |
| Monitor runs whenever the following DTCs not present | None |
| DMA communication error | Not detected |
| Difference of main throttle position and sub throttle position | 0.3 V or higher |
| Stop light switch signal (CPU) and stop light switch signal (Monitor IC) | Different |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.READ OUTPUT DTC (DTC P060E) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear the DTC (Click here).
Turn the ignition switch off and turn the Techstream off.
Disconnect the Techstream.
Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
Connect the cable to the negative (-) battery terminal.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Wait 16 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read DTCs.
| Result | Proceed to |
| DTC is not output | A |
| DTC P060E is output | B |
|
| ||||
| A | ||
| ||