The thermistor assembly is installed in the front part of the cooler condenser assembly to detect the ambient temperature and control the air conditioner. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the thermistor assembly changes in accordance with the cooler thermistor temperature (ambient temperature). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier assembly applies a voltage (5 V) to the thermistor assembly and reads voltage changes as changes in the resistance of the thermistor assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1412 | Ambient Temperature Sensor Circuit | Open or short in thermistor assembly circuit | ·
Thermistor assembly ·
Harness or connector between thermistor assembly and air conditioning amplifier assembly ·
Air conditioning amplifier assembly |
Memorized
(4 seconds or more)*1 |
*1: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
If the ambient temperature is approximately -52.9°C (-63.22°F) or lower, DTC B1412 may be output even though the system is normal.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Tester Display |
|---|
| Ambient Temp Sensor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
C
Remove the thermistor assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL
Inspect the thermistor assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A25 thermistor assembly connector.
Disconnect the F3 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F3-5 (TAM) - A25-2 | Always | Below 1 Ω |
| F3-34 (SG-2) - A25-1 | Always | Below 1 Ω |
| F3-5 (TAM) or A25-2 - Body ground | Always | 10 kΩ or higher |
| F3-34 (SG-2) or A25-1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG