1.ADJUST COMPRESSOR OIL
When replacing the cooler compressor with pulley assembly with a new one.
Remove the drain bolt (washer).
| *a | Drain bolt (washer) |
Gradually discharge the refrigerant gas from the service valve. Then drain the following amount of oil from the new cooler compressor with pulley assembly before installation, so that the amount of oil contained in it is the same as that in the cooler compressor with pulley assembly to be replaced.
Standard: (The amount of oil inside a new cooler compressor with pulley assembly: 60 (+12) cc) - (The amount of oil remaining in the removed cooler compressor with pulley assembly A + oil remaining in the reserve chamber B) = (The amount of oil to be removed when replacing the cooler compressor with pulley assembly)
A new cooler compressor with pulley assembly is filled with sufficient oil for the whole cycle. Therefore, it is necessary to drain residual oil from the condenser and cooling unit. Example: If A is 20 cc and B is 25 cc, A+B=45 cc. Since this time 60 cc - 45 cc =15 cc, drain 15 cc of the oil from the new cooler compressor with pulley assembly.
When A + B exceeds the standard oil fill volume specified for the cooler compressor with pulley assembly by part number, install the cooler compressor with pulley assembly without adjusting the oil volume. Example: If A is 40 cc and B is 25 cc, A+B is greater than 60 cc and less than 72 cc, so install the cooler compressor with pulley assembly as is.
When checking the compressor oil level, observe the precautions for cooler removal/installation.
If a new cooler compressor with pulley assembly is installed without removing the same amount of oil as is remaining in the vehicle pipes, the amount of oil will be too large. This prevents heat exchange in the refrigerant cycle and will cause a refrigeration failure.
If the amount of oil remaining in the removed cooler compressor with pulley assembly is too low, check for an oil leak.
Use ND-OIL 8 or equivalent for compressor oil.
Install the drain bolt (washer).
If draining the oil is difficult, drain the oil using the following procedure:
Do not allow the pulley to come into contact with the compressor oil.
Remove the suction seal cap.
Lightly shake the compressor with the suction port facing down, and drain the oil (*1).
With the DL pulley facing down, rotate the pulley in the direction shown by the arrow 10 times at a rate of approximately once every 2 seconds (*2).
If the pulley is rotated, refrigerant or oil might splash out. Thus, keep your face away from the compressor port.
Rotate the pulley once in the direction shown by the arrow while quickly turning the compressor so the pulley is up (*3).
Proceed with the above procedure (*1) and drain the oil (*4).
Drain the oil by repeating the procedures above approximately 5 times (from (*2) to (*4)).
88320
2.INSTALL COOLER COMPRESSOR WITH PULLEY ASSEMBLY
Install the cooler compressor with pulley assembly with the 3 bolts.
Tighten the bolts in the order shown in the illustration to install the cooler compressor with pulley assembly.
88712
3.CONNECT NO. 1 COOLER REFRIGERANT SUCTION HOSE
Remove the attached vinyl tape from the No. 1 cooler refrigerant suction hose.
Apply sufficiently compressor oil to a new O-ring and fitting surface of the cooler compressor with pulley assembly.
ND-OIL 8 or equivalent
Install the O-ring onto the No. 1 cooler refrigerant suction hose.
Connect the No. 1 cooler refrigerant suction hose to the cooler compressor with pulley assembly with the bolt.
88711
4.CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
Remove the attached vinyl tape from the No. 1 cooler refrigerant discharge hose.
Apply sufficiently compressor oil to a new O-ring and fitting surface of the cooler compressor with pulley assembly.
ND-OIL 8 or equivalent
Install the O-ring onto the No. 1 cooler refrigerant discharge hose.
Connect the No. 1 cooler refrigerant discharge hose to the cooler compressor with pulley assembly with the bolt.
16361A
5.INSTALL FAN AND GENERATOR V BELT (for 1NZ-FE)
16361A
6.INSTALL FAN AND GENERATOR V BELT (for 2NZ-FE)
7.CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
8.WARM UP ENGINE
9.INSPECT FOR REFRIGERANT LEAK