Home › Power Source / Network › 1NZ-FE BATTERY / CHARGING › GENERATOR › 2013.08–2016.10
RM30M0E _57 Power Source / Network _017107 1NZ-FE BATTERY / CHARGING _0090210 GENERATOR A

1NZ-FE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 11212 3.REMOVE NO. 2 CYLINDER HEAD COVER

Hide 16361A 4.REMOVE FAN AND GENERATOR V BELT

Hide 82121 5.DISCONNECT ENGINE WIRE

a.
A310444

Remove the terminal cap.


b.
A307885

Disconnect the generator with regulator assembly connector.


c.

Disengage the 2 clamps to disconnect the engine wire from the clamp and intake manifold.


d.

Remove the nut to disconnect the engine wire from terminal B.


Hide 16381 6.REMOVE FAN BELT ADJUSTING BAR

a.
A310445

Remove the bolt, nut and fan belt adjusting bar from the generator with regulator assembly and oil pump assembly.


Hide 27060 7.REMOVE GENERATOR WITH REGULATOR ASSEMBLY

a.
A300052

Remove the bolt and generator with regulator assembly from the cylinder block sub-assembly.