1.INSTALL HEATED OXYGEN SENSOR (for Sensor 1)
| *a | Fulcrum Length 30 mm |
| *b | Fulcrum Length 300 mm |
Using SST, install the heated oxygen sensor to the exhaust manifold.
If a component has been dropped or subjected to a strong impact, replace the heated oxygen sensor.
This torque value is effective when SST is parallel to the torque wrench.
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 300 mm (11.81 in.).
If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
17167
2.INSTALL NO. 1 EXHAUST MANIFOLD HEAT INSULATOR
Install the No. 1 exhaust manifold heat insulator to the exhaust manifold with the 3 bolts.
3.INSTALL WIRE HARNESS CLAMP BRACKET
Install the wire harness clamp bracket to the cylinder head sub-assembly with the bolt.
Engage the clamp to connect the wire harness to the wire harness clamp bracket.
Engage the 2 clamps to connect the heated oxygen sensor wire to the wire harness clamp bracket.
Connect the heated oxygen sensor connector.
11212
4.INSTALL NO. 2 CYLINDER HEAD COVER
5.INSPECT FOR EXHAUST GAS LEAK