The combination meter assembly controls the daytime running lights.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Remove the DRL relay from No. 3 relay block.
Inspect the DRL relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 3 Relay Block |
| *a | DRL Relay Holder |
Remove the DRL relay from the No. 3 relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 3 - Body ground | Always | 11 to 14 V |
| Relay terminal 1 - Body ground |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the DRL relay from No. 3 relay block.
Disconnect the A57 daytime running light assembly LH connector.
Disconnect the A56 daytime running light assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 5 - A57-2 (B) | Always | Below 1 Ω |
| Relay terminal 5 - A56-2 (B) | Always | Below 1 Ω |
| A57-1 (E) - Body ground | Always | Below 1 Ω |
| A56-1 (E) - Body ground | Always | Below 1 Ω |
| Relay terminal 5 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the DRL relay from No. 3 relay block.
Disconnect the F38 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 2 - F38-13 (DRLE) | Always | Below 1 Ω |
| Relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| F38-13 (DRLE) -Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG