MALFUNCTION DESCRIPTION
These DTCs are stored when the generator temperature sensor output is abnormal. The cause of this malfunction may be one of the following:
Hybrid vehicle control ECU internal malfunction
Generator temperature sensor internal malfunction
Open or short in generator temperature sensor
The connectors are not connected properly
Foreign matter or water on the connector terminals
Open or short in wire harness
If any of these DTCs are stored, the generator temperature sensor is malfunctioning and the self-protection function may not operate. Therefore under certain high load driving condition, the temperature of the generator (MG1) becomes high. If the self-protection function does not operate, the generator (MG1) may malfunction and cause the vehicle to enter fail-safe mode.
The resistance of the thermistor built into the generator temperature sensor changes in accordance with changes in generator (MG1) temperature. The lower the generator (MG1) temperature, the higher the thermistor resistance. Conversely, the higher the generator (MG1) temperature, the lower the resistance.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground | Short to ground in the generator temperature sensor circuit
(1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Generator temperature sensor (Hybrid vehicle transaxle assembly) |
Comes on | Master Warning: Comes on |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open | Open or short to +B in the generator temperature sensor circuit
(1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Generator temperature sensor (Hybrid vehicle transaxle assembly) |
Comes on | Master Warning: Comes on |
| DTC No. | Data List |
|---|---|
| P0A3611 | Generator Temperature |
| P0A3615 |
After confirming that DTC P0A3611 or P0A3615 is output, use the GTS to check "Generator Temperature" in the Data List.
| Displayed Temperature | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit or short to +B |
| 215°C (419°F) | Short to ground |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
With ignition switch ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Check that the intermediate connector which connects the generator temperature sensor to the hybrid vehicle control ECU is securely connected with no deformation, and that there is no contamination by water or foreign matter.
For vehicles in which the intermediate connector is inside the relay block, check for signs of water intrusion inside the relay block.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connectors.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Check the connection condition of the generator temperature sensor connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Pre-procedure1
None.
Procedure1
Read the Data List.
| Tester Display |
|---|
| Generator Temperature |
| Result | Proceed to |
|---|---|
| The value of Generator Temperature is -40°C | A |
| The value of Generator Temperature is 215°C | B |
| None of the above conditions are met | C |
-40°C (-40°F)
215°C (419°F)
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
Disconnect the D59 generator temperature sensor connector.
Procedure1
| *a | Component without harness connected
(Generator Temperature Sensor (Hybrid Vehicle Transaxle Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D59-5 (GMT) - D59-4 (GMTG) | Ignition switch off | 0.3338 to 1487 kΩ |
Terminal No. 3 on the component side connector is empty.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the D59 generator temperature sensor connector.
OK
NG
Pre-procedure1
Connect terminals 45 (GMT) and 46 (GMTG) of the A68 hybrid vehicle control ECU connector.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
Procedure1
Read the Data List.
| Tester Display |
|---|
| Generator Temperature |
| GTS Display | Condition | Specified Condition |
|---|---|---|
| Generator Temperature | Terminals A68-45 (GMT) and A68-46 (GMTG) connected
Ignition switch ON |
215°C (419°F) |
| Result | Proceed to |
|---|---|
| The value of Generator Temperature is 215°C | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
Disconnect the D59 generator temperature sensor connector.
Procedure1
| *a | Component without harness connected
(Generator Temperature Sensor (Hybrid Vehicle Transaxle Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D59-5 (GMT) - D59-4 (GMTG) | Ignition switch off | 0.3338 to 1487 kΩ |
Terminal No. 3 on the component side connector is empty.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the D59 generator temperature sensor connector.
OK
NG
Pre-procedure1
Disconnect the D59 generator temperature sensor connector.
Disconnect the A68 hybrid vehicle control ECU connector.
Procedure1
| *a | Front view of wire harness connector
(to Generator Temperature Sensor) |
| *b | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D59-5 (GMT) - A68-45 (GMT) | Ignition switch off | Below 1 Ω |
| D59-4 (GMTG) - A68-46 (GMTG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D59-5 (GMT) or A68-45 (GMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| D59-4 (GMTG) or A68-46 (GMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A68 hybrid vehicle control ECU connector.
Reconnect the D59 generator temperature sensor connector.
OK
NG