Home › Power Source / Network › M15A-FKS (BATTERY / CHARGING) › GENERATOR (for 80A Type)
RM36W0E _57 Power Source / Network _087763 M15A-FKS BATTERY / CHARGING _0424751 GENERATOR(for 80A Type) A

M15A-FKS BATTERY / CHARGING  GENERATOR(for 80A Type)  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR WITH REGULATOR ASSEMBLY

a.

Install the generator with regulator assembly with the bolt and 2 nuts.

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)


b.

Install the wire harness clamp bracket to the generator with regulator assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


c.

Connect the wire harness to terminal B with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


d.

Close the terminal cap.


e.

Connect the 2 connector.


f.

Engage the clamp.


Hide 16361A 2.INSTALL V-RIBBED BELT

Hide 3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function thatcompletes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART