Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for HV Model) › 2020.03–2020.09
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0420299 AIR CONDITIONING SYSTEM(for HV Model) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  P007011  Ambient Temperature Sensor Circuit Short to Ground  


DESCRIPTION

The thermistor assembly is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system. This sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The combination meter assembly applies voltage (5 V) to the thermistor assembly and reads voltage changes due to changes in the resistance of the thermistor assembly. The air conditioning amplifier assembly communicates with the combination meter assembly via CAN communication. The combination meter assembly sends ambient temperature signal to the air conditioning amplifier assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
P007011 Ambient Temperature Sensor Circuit Short to Ground Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Short in ambient temperature sensor circuit


Detection Time:

Continuously for 4 seconds or more


·

Thermistor assembly

·

Harness or connector

·

Combination meter assembly

·

Air conditioning amplifier assembly


Memorized

WIRING DIAGRAM

E436628E01
0.615,1.865 2.167,2.208 1.552,0.344 10 false Air Conditioning Amplifier Assembly 0.677,4.052 2.365,4.344 1.688,0.292 10 false Thermistor Assembly 4.854,4.104 7.021,4.438 2.167,0.333 10 false Combination Meter Assembly 0.667,3.885 1.052,4.135 0.385,0.25 10 false A52 4.854,3.927 5.146,4.156 0.292,0.229 10 false H6 2.156,2.833 2.385,3.094 0.229,0.26 10 false 2 2.146,3.313 2.375,3.573 0.229,0.26 10 false 1 1.781,2.833 2.26,3.094 0.479,0.26 10 false SO+ 1.76,3.313 2.24,3.573 0.479,0.26 10 false SO- 4.542,2.833 4.771,3.094 0.229,0.26 10 false 16 4.563,3.313 4.792,3.573 0.229,0.26 10 false 11 4.813,2.833 5.302,3.115 0.49,0.281 10 false TX1+ 4.823,3.302 5.26,3.51 0.438,0.208 10 false TX1- 0.563,4.427 2.354,4.667 1.792,0.24 10 false : CAN Communication Line

CAUTION / NOTICE / HINT

NOTICE:
·

The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>HOW TO PROCEED WITH TROUBLESHOOTING

·

When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.



PROCEDURE

1.READ VALUE USING GTS
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ambient Temperature Sensor Thermistor assembly Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual ambient temperature displayed Thermistor assembly circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display
Ambient Temperature Sensor
50003 450 101
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT THERMISTOR ASSEMBLY
2.INSPECT THERMISTOR ASSEMBLY

OK

3.CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - COMBINATION METER ASSEMBLY - BODY GROUND)

NG

3.CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - COMBINATION METER ASSEMBLY - BODY GROUND)

Pre-procedure1

a.

Disconnect the H6 combination meter assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A52-1 (SO-) or H6-11 (TX1-) - Other terminals and body ground Always 10 kΩ or higher
A52-2 (SO+) or H6-16 (TX1+) - Other terminals and body ground Always 10 kΩ or higher



Post-procedure1

c.

None


Result:
Proceed to
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR