Do not remove the generator pulley cap.
If the generator pulley cap is removed, replace the generator pulley cap and generator pulley with clutch with new ones as the correct grease amount cannot be confirmed.
If it is confirmed that the generator assembly is not generating power, it is not necessary to perform the counterclockwise check as another malfunction is suspected.
1.REMOVE V-RIBBED BELT
27415
2.INSPECT GENERATOR WITH CLUTCH PULLEY
| *A | Type A |
| *B | Type B |
| *a | Flat |
| *b | Tab |
As the inspection procedure differs depending on the type of inverter with generator pulley with clutch, confirm the generator pulley with clutch type before performing work.
|
Counterclockwise |
|
Clockwise |
Check that the generator pulley with clutch operates in accordance with the following table.
| Generator pulley with clutch type | Counterclockwise | Clockwise |
|---|---|---|
| Type A | Spins Freely | Lock |
| Type B | Lock* | Lock |
*:Rotates when a torque exceeding a certain value is applied.
If the generator pulley with clutch does not turn smoothly, does not operate as specified, or an abnormal sound is output, replace it with a new one.
3.INSTALL V-RIBBED BELT