Home › Power Source / Network › M15A-FKS (BATTERY / CHARGING) › GENERATOR (for 80A Type)
RM36W0E _57 Power Source / Network _087763 M15A-FKS BATTERY / CHARGING _0424751 GENERATOR(for 80A Type) G

M15A-FKS BATTERY / CHARGING  GENERATOR(for 80A Type)  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

NOTICE:
·

Do not remove the generator pulley cap.

·

If the generator pulley cap is removed, replace the generator pulley cap and generator pulley with clutch with new ones as the correct grease amount cannot be confirmed.



HINT:

If it is confirmed that the generator assembly is not generating power, it is not necessary to perform the counterclockwise check as another malfunction is suspected.


PROCEDURE

Hide 1.REMOVE V-RIBBED BELT

Hide 27415 2.INSPECT GENERATOR WITH CLUTCH PULLEY

a.
A406401C02
1.75,2.177 1.75,0 false 1.938,1.625 2.135,1.948 2.135,1.948 2.292,1.948 false 0.333,1.583 0.531,1.906 0.531,1.906 0.688,1.906 false 0.052,0.042 0.365,0.198 0.313,0.156 10 false *A 1.802,0.042 2.115,0.198 0.313,0.156 10 false *B 0.708,1.813 1.021,1.969 0.313,0.156 10 false *a 2.313,1.854 2.625,2.01 0.313,0.156 10 false *b
*A Type A
*B Type B
*a Flat
*b Tab


As the inspection procedure differs depending on the type of inverter with generator pulley with clutch, confirm the generator pulley with clutch type before performing work.


b.
A406402C01
0,0 0,0 false
V100135

Counterclockwise
V100136

Clockwise


Check that the generator pulley with clutch operates in accordance with the following table.

Standard:
Generator pulley with clutch type Counterclockwise Clockwise
Type A Spins Freely Lock
Type B Lock* Lock


HINT:
·

*:Rotates when a torque exceeding a certain value is applied.

·

If the generator pulley with clutch does not turn smoothly, does not operate as specified, or an abnormal sound is output, replace it with a new one.




Hide 3.INSTALL V-RIBBED BELT