Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) › 2020.07–2020.09
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0420298 AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  B142A88  Servo Motor LIN Communication Bus off  


DESCRIPTION

The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B142A88 Servo Motor LIN Communication Bus off Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Error or lost communication with each servo motor


Detection Time:

Continuously for 10 seconds or more


·

Air conditioning harness assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

Air conditioning amplifier assembly


Memorized

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Ignition switch ON ○ ○
Malfunction Error communication with each servo motor ○ -
Lost communication with each servo motor - ○
Detection Time Continuously for 10 seconds or more Continuously for 10 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored


WIRING DIAGRAM

for Dual Type


E441735E01
0.313,1.469 1.792,1.75 1.479,0.281 10 false Driver Side Air Mix*1 0.75,3.271 1.25,3.531 0.5,0.26 10 false Mode 0.177,4.823 2.198,5.115 2.021,0.292 10 false Front Passenger Side Air Mix*1 2.802,5.24 3.208,5.469 0.406,0.229 10 false GND 2.906,5 3.24,5.219 0.333,0.219 10 false M+ 3.208,5 3.438,5.198 0.229,0.198 10 false 2 3.208,5.24 3.438,5.438 0.229,0.198 10 false 5 2.948,4.188 3.281,4.406 0.333,0.219 10 false M- 2.792,3.99 3.229,4.219 0.438,0.229 10 false STE1 2.792,3.792 3.229,4.021 0.438,0.229 10 false STE2 3.219,3.698 3.448,3.896 0.229,0.198 10 false 3 3.219,3.896 3.448,4.094 0.229,0.198 10 false 4 3.208,4.104 3.438,4.302 0.229,0.198 10 false 1 2.479,2.396 2.688,2.625 0.208,0.229 10 false IC 2.823,1.802 3.229,2.031 0.406,0.229 10 false GND 2.906,1.208 3.24,1.438 0.333,0.229 10 false LIN 2.927,0.615 3.219,0.844 0.292,0.229 10 false +B 3.208,0.51 3.438,0.708 0.229,0.198 10 false 8 3.219,1.063 3.448,1.26 0.229,0.198 10 false 7 3.219,1.698 3.448,1.896 0.229,0.198 10 false 6 5.354,0.49 5.583,0.688 0.229,0.198 10 false 4 5.354,1.042 5.583,1.24 0.229,0.198 10 false 3 5.354,1.677 5.583,1.875 0.229,0.198 10 false 2 6.646,0.458 6.938,0.688 0.292,0.229 10 false +B 6.76,1.219 6.969,1.448 0.208,0.229 10 false IC 5.542,0.51 6.031,0.74 0.49,0.229 10 false BUSB 5.552,1.104 5.927,1.333 0.375,0.229 10 false BUS 5.552,1.677 6.115,1.906 0.563,0.229 10 false BUSG 0.448,5.76 0.771,6.01 0.323,0.25 10 false h7 0.438,5.938 2.885,6.448 2.448,0.51 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.302,7.813 0.625,8.063 0.323,0.25 10 false h4 0.292,7.99 2.969,8.271 2.677,0.281 10 false No. 1 Blower Damper Servo Sub-assembly 0.802,8.417 2.5,8.688 1.698,0.271 10 false : LIN Communication Line 3.469,7.833 5.021,8.365 1.552,0.531 10 false Air Conditioning Harness Assembly 5.51,7.906 7.094,8.438 1.583,0.531 10 false Air Conditioning Amplifier Assembly 5.521,7.729 5.844,7.979 0.323,0.25 10 false h6 3.208,6.573 3.438,6.771 0.229,0.198 10 false 1 3.219,6.781 3.448,6.979 0.229,0.198 10 false 4 3.219,6.99 3.448,7.188 0.229,0.198 10 false 5 3.219,7.188 3.448,7.385 0.229,0.198 10 false 2 3.219,7.396 3.448,7.594 0.229,0.198 10 false 3 2.813,6.594 3.219,6.823 0.406,0.229 10 false GND 2.906,6.802 3.24,7.021 0.333,0.219 10 false M+ 2.917,6.99 3.25,7.208 0.333,0.219 10 false M- 2.823,7.188 3.167,7.417 0.344,0.229 10 false sigA 2.823,7.385 3.208,7.615 0.385,0.229 10 false sigB 0.177,1.74 2.198,2.021 2.021,0.281 10 false Front Passenger Side Air Mix*2 0.313,5.135 1.792,5.417 1.479,0.281 10 false Driver Side Air Mix*2 2.813,8.427 3.625,8.708 0.813,0.281 10 false *1: for LHD 3.906,8.427 4.719,8.708 0.813,0.281 10 false *2: for RHD


for Single Type


E437384E01
2.292,1.823 2.656,2.01 0.365,0.188 10 false IC 5.521,6.688 6.083,6.885 0.563,0.198 10 false h6 5.51,6.865 7.073,7.188 1.563,0.323 10 false Air Conditioning Amplifier Assembly 3.104,6.771 5.448,7.177 2.344,0.406 10 false Air Conditioning Harness Assembly 0.219,6.979 3.177,7.333 2.958,0.354 10 false No. 1 Blower Damper Servo Sub-assembly 0.156,4.844 2.938,5.177 2.781,0.333 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.729,3.5 1.427,3.781 0.698,0.281 10 false Mode 0.656,1.5 1.271,1.729 0.615,0.229 10 false Air Mix 5.542,1.677 6.104,1.875 0.563,0.198 10 false BUSG 5.542,1.104 6.104,1.302 0.563,0.198 10 false BUS 5.542,0.5 6.104,0.698 0.563,0.198 10 false BUSB 6.76,1.198 7,1.396 0.24,0.198 10 false IC 5.354,0.49 5.656,0.698 0.302,0.208 10 false 4 5.354,1.042 5.656,1.25 0.302,0.208 10 false 3 5.354,1.677 5.656,1.885 0.302,0.208 10 false 2 0.781,7.469 3.083,7.844 2.302,0.375 10 false : LIN Communication Line 6.448,0.323 6.771,0.51 0.323,0.188 10 false +B 2.594,2.781 3.208,2.979 0.615,0.198 10 false STE2 2.594,2.99 3.208,3.188 0.615,0.198 10 false STE1 2.75,3.188 3.365,3.385 0.615,0.198 10 false M- 2.646,5.573 3.26,5.771 0.615,0.198 10 false GND 2.74,5.781 3.354,5.979 0.615,0.198 10 false M+ 2.75,5.979 3.365,6.177 0.615,0.198 10 false M- 2.656,6.156 3.271,6.354 0.615,0.198 10 false sigA 2.667,6.365 3.281,6.563 0.615,0.198 10 false sigB 3.031,2.677 3.333,2.885 0.302,0.208 10 false 3 3.031,2.885 3.333,3.094 0.302,0.208 10 false 4 3.031,3.094 3.333,3.302 0.302,0.208 10 false 1 3.031,3.667 3.333,3.875 0.302,0.208 10 false 2 3.031,3.875 3.333,4.083 0.302,0.208 10 false 5 3.031,5.552 3.333,5.76 0.302,0.208 10 false 1 3.031,5.771 3.333,5.979 0.302,0.208 10 false 4 3.042,5.969 3.344,6.177 0.302,0.208 10 false 5 3.042,6.167 3.344,6.375 0.302,0.208 10 false 2 3.042,6.365 3.344,6.573 0.302,0.208 10 false 3 2.729,3.677 3.344,3.875 0.615,0.198 10 false M+ 2.646,3.875 3.26,4.073 0.615,0.198 10 false GND 0.167,4.677 0.781,4.875 0.615,0.198 10 false h7 0.24,6.781 0.854,6.979 0.615,0.198 10 false h4 2.646,1.76 3,1.958 0.354,0.198 10 false GND 2.719,1.177 3.073,1.375 0.354,0.198 10 false LIN 2.76,0.594 3.031,0.802 0.271,0.208 10 false +B 3.021,1.042 3.24,1.26 0.219,0.219 10 false 7 3.021,0.479 3.219,0.635 0.198,0.156 10 false 8 3.031,1.677 3.24,1.865 0.208,0.188 10 false 6


CAUTION / NOTICE / HINT

NOTICE:

This DTC is also output when servomotor initialization has failed. When servomotor initialization has failed, repair any malfunctions and perform servomotor initialization again.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System)>INITIALIZATION


PROCEDURE

1.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
NOTICE:

When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.


Pre-procedure1

a.

Disconnect the air conditioning amplifier assembly connector.


Procedure1

b.
E437458C01
2.625,0.49 3.042,0.74 0.417,0.25 2.417,2.469 2.656,1.604 true 3.125,2.49 2.906,1.615 true 0.115,0.115 0.427,0.354 0.313,0.24 10 false *a 2.76,0.552 3.073,0.792 0.313,0.24 10 false h6 2.292,2.552 2.75,2.792 0.458,0.24 10 false BUSB 2.917,2.552 3.375,2.792 0.458,0.24 10 false BUSG
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage and resistance according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
h6-4 (BUSB) - Body ground Always 11 to 14 V


Standard Resistance:
Tester Connection Condition Specified Condition
h6-2 (BUSG) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

2.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

2.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
E389744C11
2.615,0.292 3.042,0.563 0.427,0.271 2.531,2.344 2.792,1.406 true 3.073,2.344 2.906,1.417 true 0.406,3.927 0.865,4.125 0.458,0.198 10 false GND 0.146,0.104 0.604,0.302 0.458,0.198 10 false *a 2.76,0.354 3.052,0.563 0.292,0.208 10 false h6 2.385,2.385 2.792,2.594 0.406,0.208 10 false BUS 2.948,2.396 3.385,2.625 0.438,0.229 10 false BUSG
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


a.

Using an oscilloscope, check the waveform.

Item Content
Terminal No. h6-3 (BUS) ←→ h6-2 (BUSG)
Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Ignition switch ON

OK:

Waveform is similar to that shown in the illustration.



Result:
Proceed to
OK
NG



OK

3.CONFIRM MODEL

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

3.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for LHD A
for RHD B



A

4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

B

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY
4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

Pre-procedure1

a.

Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
h6-2 (BUSG) - h7-6 (GND) Always Below 1 Ω
h6-3 (BUS) - h7-7 (LIN) Always Below 1 Ω
h6-4 (BUSB) - h7-8 (+B) Always Below 1 Ω



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

Pre-procedure1

a.

Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
h6-2 (BUSG) - h7-6 (GND) Always Below 1 Ω
h6-3 (BUS) - h7-7 (LIN) Always Below 1 Ω
h6-4 (BUSB) - h7-8 (+B) Always Below 1 Ω



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG