If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
| Symptom | Factor |
|---|---|
| No cool air comes out
(Blower control is normal) |
·
Compressor malfunction ·
Refrigerant pressure is extremely high or low ·
Refrigerant volume (low) ·
Clogged cooler condenser assembly fins ·
Cooling fan system malfunction ·
Mechanical locking of damper and damper link ·
No. 1 cooler thermistor malfunction ·
Open in air conditioner pressure sensor power source circuit ·
High inlet air temperature |
Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.
All switch indicators operate normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for Dual Type | A |
| for Single Type | B |
A
B
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Left Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Front Right Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Tester Display |
|---|
| Front Left Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Front Right Air Mix Damper Control Servo Motor |
Each damper servo motor operates.
| Result | Proceed to |
|---|---|
| OK (for HFC-134a(R134a)) | A |
| OK (for HFO-1234yf(R1234yf)) | B |
| NG | C |
A
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
B
C
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Front Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Tester Display |
|---|
| Front Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Front Air Outlet Damper Control Servo Motor |
Each damper servo motor operates.
| Result | Proceed to |
|---|---|
| OK (for HFC-134a(R134a)) | A |
| OK (for HFO-1234yf(R1234yf)) | B |
| NG | C |
A
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
B
C