Auxiliary battery power is supplied to the BATT terminal of the hybrid vehicle control ECU in order to store DTCs and freeze frame data. Even if the ignition switch is turned off, back-up power is supplied.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open | Malfunction in the hybrid vehicle control ECU back-up power source circuit
(1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Fuse |
Comes on | Master Warning: Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
With ignition switch ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors.
| *A | for RHD | *B | for LHD |
The connectors are connected securely and there are no contact pressure problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Turn the ignition switch off.
Procedure1
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H44-13 (BATT) - H44-15 (E1) | Ignition switch off | 11 to 14 V |
Post-procedure1
None.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
| *1 | Power Distribution Box Assembly |
| *2 | ECU-B NO. 2 Fuse |
Remove the ECU-B NO. 2 fuse from the power distribution box assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ECU-B NO. 2 fuse | Always | Below 1 Ω |
Post-procedure1
Reinstall the ECU-B NO. 2 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK