Home › Power Source / Network › 1KR-FE (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.07
RM36W0E _57 Power Source / Network _090846 1KR-FE BATTERY / CHARGING _0430815 CHARGING SYSTEM C

1KR-FE BATTERY / CHARGING  CHARGING SYSTEM  P062049  Generator Control Circuit Internal Electronic Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Memory Note
P062049 Generator Control Circuit Internal Electronic Failure Open or short in EXC circuit, or abnormal waveform for PH circuit.
(1 trip detection logic)
Generator assembly Charge warning light:
Comes on
DTC stored SAE Code: P0620

WIRING DIAGRAM

A457581E03
0.646,3.885 1.26,4.323 0.615,0.438 10 false Battery 1.792,0.76 2.406,0.958 0.615,0.198 10 false ALT 3.521,2.521 4.135,2.719 0.615,0.198 10 false B 4.906,2.521 5.521,2.719 0.615,0.198 10 false LIN 3.719,2.26 4.333,2.458 0.615,0.198 10 false 1 5.042,2.26 5.656,2.458 0.615,0.198 10 false 2 4.323,3.583 5.417,3.802 1.094,0.219 10 false IC Regulator 4.094,4.833 5.729,5.073 1.635,0.24 10 false Generator Assembly 1.135,5.271 3.031,5.521 1.896,0.25 10 false : LIN Communication Line 4.656,2.24 5.271,2.438 0.615,0.198 10 false D53 6.021,0.521 6.635,0.719 0.615,0.198 10 false LIN 5.604,0.521 6.219,0.719 0.615,0.198 10 false D50 5.604,1.417 6.219,1.615 0.615,0.198 10 false A55 6,1.438 6.615,1.635 0.615,0.198 10 false E1 6.177,2.052 6.698,2.396 0.521,0.344 10 false ECM 5.635,0.323 6.25,0.521 0.615,0.198 10 false 76 5.635,1.208 6.25,1.406 0.615,0.198 10 false 4 4.688,2.771 5.302,2.969 0.615,0.198 10 false LIN 3.885,2.771 4.5,2.969 0.615,0.198 10 false B 3.896,3.635 4.51,3.833 0.615,0.198 10 false PH 3.875,4.219 4.49,4.417 0.615,0.198 10 false EXC 3.865,4.49 4.479,4.688 0.615,0.198 10 false GND 3.323,2.24 3.938,2.438 0.615,0.198 10 false D87 0.188,0.125 2.573,0.365 2.385,0.24 12 false for 80A Type:

A457582E03
0.583,3.99 1.219,4.354 0.635,0.365 10 false Battery 1.76,0.813 2.375,1.01 0.615,0.198 10 false ALT 3.469,2.635 4.083,2.833 0.615,0.198 10 false B 4.875,2.646 5.49,2.844 0.615,0.198 10 false LIN 3.646,2.396 4.26,2.594 0.615,0.198 10 false 1 4.99,2.396 5.604,2.594 0.615,0.198 10 false 2 4.313,3.615 5.406,3.833 1.094,0.219 10 false IC Regulator 4.094,4.677 5.74,4.917 1.646,0.24 10 false Generator Assembly 1.063,5.385 2.927,5.615 1.865,0.229 10 false : LIN Communication Line 4.594,2.354 5.208,2.552 0.615,0.198 10 false D53 5.948,0.677 6.563,0.875 0.615,0.198 10 false LIN 5.563,0.656 6.177,0.854 0.615,0.198 10 false D50 5.542,1.542 6.156,1.74 0.615,0.198 10 false A55 5.938,1.563 6.552,1.76 0.615,0.198 10 false E1 6.177,2.135 6.729,2.448 0.552,0.313 10 false ECM 5.594,0.458 6.208,0.656 0.615,0.198 10 false 76 5.583,1.344 6.198,1.542 0.615,0.198 10 false 4 3.833,3.542 4.448,3.74 0.615,0.198 10 false PH 3.833,4.083 4.448,4.281 0.615,0.198 10 false EXC 3.833,4.344 4.448,4.542 0.615,0.198 10 false GND 3.813,2.906 4.427,3.104 0.615,0.198 10 false B 4.635,2.896 5.25,3.094 0.615,0.198 10 false LIN 3.271,2.354 3.885,2.552 0.615,0.198 10 false D87 0.115,0.125 2.688,0.365 2.573,0.24 12 false for 100A Type:

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHARGING CIRCUIT WITHOUT LOAD

OK

2.CHARGING CIRCUIT WITH LOAD

NG