Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) › 2020.07–2020.09
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0420298 AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  P053511  Evaporator Temperature Sensor Circuit Short to Ground  


DESCRIPTION

The No. 1 cooler thermistor is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
P053511 Evaporator Temperature Sensor Circuit Short to Ground Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Short in evaporator temperature sensor circuit


Detection Time:

Continuously for 4 seconds or more


·

No. 1 cooler thermistor

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly


Memorized

WIRING DIAGRAM

E332458E80
1.719,0.708 2,0.948 0.281,0.24 10 false 2 1.719,1.167 2,1.406 0.281,0.24 10 false 1 0.271,1.948 1.854,2.146 1.583,0.198 10 false No. 1 Cooler Thermistor 2.177,1.802 4.479,2.208 2.302,0.406 10 false Air Conditioning Harness Assembly 4.771,1.771 5.052,2.01 0.281,0.24 10 false h6 4.771,1.927 7.083,2.24 2.313,0.313 10 false Air Conditioning Amplifier Assembly 4.833,0.677 5.115,0.917 0.281,0.24 10 false 6 4.833,1.177 5.115,1.417 0.281,0.24 10 false 5 5,0.688 5.521,0.969 0.521,0.281 10 false TE 5,1.177 5.469,1.427 0.469,0.25 10 false SG-3 5.875,0.271 6.156,0.51 0.281,0.24 10 false 5 V 6.469,0.792 6.75,1.031 0.281,0.24 10 false AD 0.271,1.781 0.74,2.031 0.469,0.25 10 false h5

PROCEDURE

1.READ VALUE USING GTS
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual evaporator temperature displayed No. 1 cooler thermistor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display
Evaporator Fin Thermistor
50003 450 105
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT NO. 1 COOLER THERMISTOR
2.INSPECT NO. 1 COOLER THERMISTOR

OK

3.CONFIRM MODEL

NG

3.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for LHD A
for RHD B



A

4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

B

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY
4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

Pre-procedure1

a.

Remove the air conditioning harness assembly.

HINT:

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for LHD)>DISASSEMBLY



Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
h5-1 or h6-5 (SG-3) - Other terminals and body ground Always 10 kΩ or higher
h5-2 or h6-6 (TE) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

Pre-procedure1

a.

Remove the air conditioning harness assembly.

HINT:

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for RHD)>DISASSEMBLY



Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
h5-1 or h6-5 (SG-3) - Other terminals and body ground Always 10 kΩ or higher
h5-2 or h6-6 (TE) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG