Home › Brake › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS › BRAKE CONTROL POWER SUPPLY › from 2020.07
RM36W0E _54 Brake _088016 BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS _0432240 BRAKE CONTROL POWER SUPPLY A

BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS  BRAKE CONTROL POWER SUPPLY  INSTALLATION  


PROCEDURE

Hide 89686 1.INSTALL NO. 1 BRAKE CONTROL POWER SUPPLY BRACKET

a.
C436329C01
1.5,1.156 2,0.542 2,0.542 2.167,0.542 true 1.354,0.521 1.885,0.115 1.885,0.115 2.052,0.115 true 1,1.917 1.167,1.917 1.167,1.917 1.635,1.302 true 2.198,0.469 2.51,0.667 0.313,0.198 10 false *a 2.094,0.052 2.406,0.25 0.313,0.198 10 false *b 0.813,1.823 1.125,2.021 0.313,0.198 10 false *b
*a Arrow
*b Align the hole on the No. 1 brake control power supply bracket with the protrusion of the brake control power supply assembly.


Install the No. 1 brake control power supply bracket with 4 bolts.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)

NOTICE:
·

Do not drop the brake control power supply assembly. If it is dropped, replace it with a new one.

·

Do not hold the brake control power supply assembly by the connector.

·

Make sure to install the No. 1 brake control power supply bracket with its arrow facing the connector.




Hide 89680 2.INSTALL BRAKE CONTROL POWER SUPPLY ASSEMBLY

NOTICE:
·

Do not hold the brake control power supply assembly by the connector.

·

Do not drop the brake control power supply assembly when carrying it.



a.
C438727C01
0,0 0,0 false

Connect the brake control power supply assembly connector.

i.

Connect the brake control power supply assembly connector and push down the lock lever to engage the claw as shown in the illustration.

NOTICE:
·

When connecting the brake control power supply assembly connector, make sure that the connecting parts of the brake control power supply assembly connector are free of dirt, water or other foreign matter.

·

Be sure to securely connect the brake control power supply assembly connector.





b.

Engage the hook and install the brake control power supply assembly with the 2 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


c.

Install the floor carpet.


Hide 3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART