When the temperature sensor inside the electric brake booster (brake booster with master cylinder assembly) meets the detection conditions, this DTC is stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from |
|---|---|---|---|---|
| C148A1C | Electronic Brake Booster Motor "A" Temperature Sensor "A" Circuit Voltage Out of Range | Temp sensor 1 output voltage is 3.27 V or more, or 0.2 V or less, for 0.6 seconds or more. | Electric brake booster (brake booster with master cylinder assembly) | Brake Booster |
| C148F62 | Electronic Brake Booster Motor Temperature "A" / "B" Signal Compare Failure | The sum of temp sensor 1 and temp sensor 2 output voltages is within the range of 3.17 V to 3.43 V for 0.6 seconds or more. | Electric brake booster (brake booster with master cylinder assembly) | Brake Booster |
| C149A1C | Electronic Brake Booster Motor "A" Temperature Sensor "B" Circuit Voltage Out of Range | Temp sensor 2 output voltage is 3.27 V or more, or 0.2 V or less, for 0.6 seconds or more. | Electric brake booster (brake booster with master cylinder assembly) | Brake Booster |
After replacing the electric brake booster (brake booster with master cylinder assembly), perform "Calibration" after performing "Reset Memory".
Choose the model to be inspected
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE MASTER CYLINDER (for HV Model LHD)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE MASTER CYLINDER (for HV Model RHD)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT