When the ignition switch is turned on (IG), the battery voltage is applied to IGSW of the ECM. When the transistor in the MREL circuit operates, current flows from the battery to ground through the drive circuit of the EFI-MAIN NO. 1 relay, thus operating the relay which supplies power to the +B and +B2 terminals of the ECM.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A106-10(E1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A106-2(IGP) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the EFI-MAIN NO. 1 relay.
Click hereEngine / Hybrid System>G16E-GTS (ENGINE CONTROL)>RELAY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Remove the EFI-MAIN NO. 1 relay, EFI-MAIN NO. 3 relay and EDU relay from the No. 1 engine room relay block assembly.
Remove the EFI-MAIN NO. 2 relay from the No. 5 luggage room relay block assembly.
Remove the EFI-MAIN NO. 2 and EFI-MAIN NO. 3 relays connected between the checked terminals as the coil inside the relay influences the measurement value.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2(EFI-MAIN NO.1 relay) - A106-15(MREL) | Always | Below 1 Ω |
| 5(EFI-MAIN NO.1 relay) - A106-9(+B) | Always | Below 1 Ω |
| 5(EFI-MAIN NO.1 relay) - A106-35(+B2) | Always | Below 1 Ω |
| 2(EFI-MAIN NO.1 relay) or A106-15(MREL) - Body ground and other terminals | Always | 10 kΩ or higher |
| 2(EFI-MAIN NO.1 relay), A106-15(MREL), A106-9(+B) or A106-35(+B2) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block Assembly |
| *2 | EFI-MAIN NO. 1 Relay |
Remove the EFI-MAIN NO. 1 relay from the No. 1 engine room relay block assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1(EFI-MAIN NO. 1 relay) - Body ground | Always | 11 to 14 V |
| 3(EFI-MAIN NO. 1 relay) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the IGP relay.
Click hereEngine / Hybrid System>G16E-GTS (ENGINE CONTROL)>RELAY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Remove the EFI-MAIN NO. 1 relay, EFI-MAIN NO. 3 relay and EDU relay from the No. 1 engine room relay block assembly.
Remove the EFI-MAIN NO. 2 relay from the No. 5 luggage room relay block assembly.
Remove the EFI-MAIN NO. 2 and EFI-MAIN NO. 3 relays connected between the checked terminals as the coil inside the relay influences the measurement value.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5(IGP relay) - A106-2(IGP) | Always | Below 1 Ω |
| 5(IGP relay) or A106-2(IGP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGP relay from the No. 1 engine room relay block assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3(IGP relay) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGP relay from the No. 1 engine room relay block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2(IGP relay) - Body ground | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK (w/ Entry and Start System) | A |
| OK (w/o Entry and Start System) | B |
| NG | C |
A
B
C
Disconnect the certification ECU (smart key ECU assembly) connector.
Disconnect the instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H45-24(IGPD) - 1(IGP relay) | Always | Below 1 Ω |
| H45-24(IGPD) or 1(IGP relay) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ignition or starter switch assembly connector.
Disconnect the instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H54-8(IG1) - 1(IGP relay) | Always | Below 1 Ω |
| H54-8(IG1) or 1(IGP relay) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>G16E-GTS (STARTING)>IGNITION SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG