1.CHECK AUXILIARY BATTERY CONDITION
If the auxiliary battery is weak or if the engine is difficult to start, recharge the auxiliary battery and perform inspections again before returning the vehicle to the customer.
Check the auxiliary battery for damage or deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.
Check the electrolyte level in each cell.
If the electrolyte level is below the lower line, add distilled water to each cell. Then, recharge the auxiliary battery and check the electrolyte specific gravity.
1.25 or higher at 20°C (68°F)
If the electrolyte level is above the lower line, check the auxiliary battery voltage while cranking the engine. If the auxiliary battery voltage is less than 9.6 V, recharge or replace the auxiliary battery.
Before checking the auxiliary battery voltage, turn off all the electrical systems (headlights, blower motor, rear window defogger, etc.).
Check the voltage.
Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the auxiliary battery.
Measure the auxiliary battery voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive (+) terminal - Negative (-) terminal | 20°C (68°F) | 12.3 V or higher |
If the result is not as specified, recharge or replace the auxiliary battery.
2.CHECK BATTERY TERMINAL, BATTERY STATE SENSOR ASSEMBLY
Check whether the battery state sensor assembly is deformed or cracked.
Check that the battery terminals are not loose or corroded.
If a terminal is loose or corroded, tighten or clean the terminal.
3.CHECK FUSES
Measure the resistance of each fuse for the charging system.
The fuses shown in System Diagram are related to the charging system.
Below 1 Ω
If the result is not as specified, replace the fuse.
16361A
4.INSPECT FAN AND GENERATOR V BELT
5.INSPECT GENERATOR ASSEMBLY WIRING
Visually check the generator assembly wiring.
Check that the wiring is in good condition.
6.CHECK FOR ABNORMAL NOISE
Check for abnormal noises from the generator assembly.
Check that no abnormal noises are heard from the generator assembly while the engine is running.
If noise occurs, refer to Problem Symptoms Table.
Click herePower Source / Network>G16E-GTS (BATTERY / CHARGING)>CHARGING SYSTEM>PROBLEM SYMPTOMS TABLE
7.INSPECT CHARGING CIRCUIT WITHOUT LOAD
| *1 | Auxiliary Battery |
| *2 | Generator Assembly |
| *a | Terminal B |
Connect a voltmeter and an ammeter to the charging circuit as follows.
If a battery/generator assembly tester is available, connect the tester to the charging circuit in accordance with the manufacturer's instructions.
Disconnect the wire from terminal B of the generator assembly and connect it to the negative (-) lead of the ammeter.
Connect the ammeter positive (+) lead to terminal B of the generator assembly.
Connect the voltmeter positive (+) lead to the positive (+) terminal of the auxiliary battery.
Ground the voltmeter negative (-) lead.
Check the charging circuit.
Maintain the engine speed at 2000 rpm and check the readings on the ammeter and voltmeter.
10 A or less
13.2 to 14.8 V
If the result is not as specified, repair or replace the generator assembly.
8.INSPECT CHARGING CIRCUIT WITH LOAD
With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the "HI" position.
Check the reading on the ammeter.
30 A or higher
If the result is not as specified, repair or replace the generator assembly.
If the auxiliary battery is fully charged, the reading will sometimes be less than the standard current. In this case, add more electrical load (operate the wipers, rear window defogger, etc.) and check the reading on the ammeter again.
9.INSPECT CHARGING SYSTEM
Check the harness and connector.
Disconnect the D104 ECM connector.
Disconnect the D53 generator assembly connector.
Disconnect the O68 battery state sensor assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D104-62 (LIN) - D53-2 (LIN) | Always | Below 1 Ω |
| D104-62 (LIN) or D53-2 (LIN) - Body ground | Ignition switch off
(while LIN communication stopped) |
10 kΩ or higher |
| D104-62 (LIN) - O68-2 (LIN) | Always | Below 1 Ω |
| D104-62 (LIN) or O68-2 (LIN) - Body ground | Ignition switch off
(while LIN communication stopped) |
10 kΩ or higher |
If the result is not as specified, repair or replace the harness or connector.