Home › Power Source / Network › G16E-GTS (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.09
RM36W0E _57 Power Source / Network _095208 G16E-GTS BATTERY / CHARGING _0447332 CHARGING SYSTEM C

G16E-GTS BATTERY / CHARGING  CHARGING SYSTEM  P160200  Deterioration of Battery Low Capacity  


DESCRIPTION

The auxiliary battery condition is calculated from the voltage when the engine is running (except when cranking) and then output to the ECM. A DTC is output when auxiliary battery degradation is determined based on this signal.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Note
P160200 Deterioration of Battery Low Capacity While engine is running (except when cranking), auxiliary battery capacity is abnormally low for 10 seconds or more.
(1 trip detection logic)
·

Auxiliary battery

·

Wire harness or connector


Does not come on SAE Code: P1602

WIRING DIAGRAM

A475237E04
0.885,2.313 2.052,2.583 1.167,0.271 10 false Auxiliary Battery 5.24,3.188 5.781,3.521 0.542,0.333 10 false ECM 5.354,0.823 5.969,1.021 0.615,0.198 10 false BATT 5.344,2.385 5.656,2.583 0.313,0.198 10 false E1 5.24,3 5.698,3.198 0.458,0.198 10 false A106 5.094,0.823 5.25,1.021 0.156,0.198 10 false 1 5.031,2.229 5.344,2.427 0.313,0.198 10 false 10 2.615,1.156 3.302,1.406 0.688,0.25 10 false EFI NO. 1 0.76,1.438 1.385,1.635 0.625,0.198 10 false ENG

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHECK CHARGING SYSTEM

OK

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF ECM)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF ECM)

Pre-procedure1

a.

Disconnect the D106 ECM connector.


Procedure1

b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
D106-1 (BATT) - Body ground Always 11 to 14 V



Post-procedure1

c.

None


Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR