Home › Power Source / Network › G16E-GTS (BATTERY / CHARGING) › BATTERY CURRENT SENSOR › from 2020.09
RM36W0E _57 Power Source / Network _095208 G16E-GTS BATTERY / CHARGING _0449412 BATTERY CURRENT SENSOR A

G16E-GTS BATTERY / CHARGING  BATTERY CURRENT SENSOR  INSTALLATION  


PROCEDURE

Hide 28850C 1.INSTALL BATTERY STATE SENSOR ASSEMBLY

a.

Install the battery state sensor assembly to the auxiliary battery and tighten the nut.

Torque:
5.4 N*m (55 kgf*cm, 48 in.*lbf)


b.

Connect the No. 2 frame wire to the battery state sensor assembly with the nut.

Torque:
7.6 N*m (77 kgf*cm, 67 in.*lbf)


c.

Connect the battery state sensor assembly connector.


Hide 3. INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function thatcompletes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART