The telephone transceiver assembly sends a mute signal to the stereo component amplifier assembly.
The stereo component amplifier assembly controls the volume according to the mute signal from the telephone transceiver assembly.
When replacing the telephone transceiver assembly, make sure to replace it with a new one.
Depending on the parts that are replaced during vehicle inspection or maintenance, performing initialization, registration or calibration may be needed. Refer to Precaution for Audio and Visual System.
Click hereAudio / Visual / Telematics>AUDIO / VIDEO>AUDIO AND VISUAL SYSTEM>PRECAUTION
| *a | Component with harness connected
(Telephone Transceiver Assembly) |
Remove the telephone transceiver assembly with the connector(s) still connected.
Click hereAudio / Visual / Telematics>TELEMATICS>TELEMATICS TRANSCEIVER>REMOVAL
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H85-14 (MUTE) - Body ground | Ignition switch ON, audio system playing
→ Emergency call mode |
2.0 V or higher
→ Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| except G16E-GTS | A |
| for G16E-GTS | B |
A
B
Disconnect the H137 stereo component amplifier assembly connector.
Disconnect the H85 telephone transceiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H137-24 (TMUT) - H85-14 (MUTE) | Always | Below 1 Ω |
| H137-24 (TMUT) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H85 telephone transceiver assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| H85-14 (MUTE) - Body ground | Ignition switch ON | 2.0 V or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the O122 stereo component amplifier assembly connector.
Disconnect the H85 telephone transceiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O122-24 (TMUT) - H85-14 (MUTE) | Always | Below 1 Ω |
| O122-24 (TMUT) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H85 telephone transceiver assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| H85-14 (MUTE) - Body ground | Ignition switch ON | 2.0 V or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG