When the stop and start system does not operate, check whether the operation is prohibited because the auxiliary battery conditions are not met.
| Hood Courtesy Switch | Battery Current | Battery Fluid Temperature (Start) | Battery Fluid Temperature |
| Idling Stop Rate | Total Idling Stop Rate | Integrated Current | Status of Battery Charge Control |
| Minimum Voltage (Cranking) | Minimum Voltage (Starter Solenoid Engagement) | State of BBC | Stop&Start Operating Permission (Power Management) |
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | Stop&Start Operating Permission (Minimum Voltage (Cranking)) | Stop&Start Operating Permission (Integrated Current) | Stop&Start Operating Prohibition (Jump Start) |
| Stop&Start Operating Prohibition (Manual Start for the First Time) | Battery Type | Ambient Temperature | Alternator Status |
If the Data List item Stop&Start Operating Permission (Power Management) is "NG" even after correcting a certain problem using the diagnostic troubleshooting procedures, the problem may be due to the auxiliary battery charge amount being temporarily low or the auxiliary battery may be deteriorated. However, there may be multiple overlapping conditions which are causing system operation to be prohibited, so make sure to always confirm all the diagnostic troubleshooting procedures.
Check whether the multi-information display displayed that the specified auxiliary battery is not equipped.
The multi-information display is displayed when the voltage decreases below the minimum voltage necessary for starting the non-specified auxiliary battery when stop and start control is operated.
| Result | Proceed to |
|---|---|
| No display | A |
| Displayed in past | B |
A
B
Enter the following menus: Powertrain / Stop and Start / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
B
Check whether stop and start control was prohibited based on the auxiliary battery conditions or other conditions.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Permission (Power Management).
| Tester Display |
|---|
| Stop&Start Operating Permission (Power Management) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Permission (Power Management) | Permission of stop and start control based on the auxiliary battery conditions | NG / OK | OK: Stop and start control is permitted due to auxiliary battery condition, or Active Test (forced permission) is performed | - |
| Result | Proceed to |
|---|---|
| NG is displayed | A |
| OK is displayed | B |
A
B
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
| Tester Display |
|---|
| Battery Type |
Check the "Battery Type" Data List Item.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set auxiliary battery type | Specified / Other | Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery |
- |
Check whether the auxiliary battery is specified or not specified.
| GTS Display | Proceed to |
|---|---|
| Specified | A |
| Other | B |
A
B
Check whether stop and start control was prohibited based on the jump start auxiliary battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Prohibition (Jump Start).
| Tester Display |
|---|
| Stop&Start Operating Prohibition (Jump Start) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit / Prohibit | Permit: Except for jump start conditions | When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Jump start conditions: Engine started with the engine hood or back door*1 open and the ignition switch turned START |
*1: for 3 Door
| Result | Proceed to |
|---|---|
| Permit is displayed (for Manual Transaxle) | A |
| Permit is displayed (for CVT) | B |
| Prohibit is displayed | C |
A jump start is determined if the engine is started with the engine hood or back door*1 open.
After turning the ignition switch off and waiting approximately 30 seconds, a jump start is determined to have not occurred if the engine started with the engine hood or back door*1 closed.
*1: for 3 Door
A
B
C
Check whether the stop and start control was prohibited based on the manual start auxiliary battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Prohibition (Manual Start for the First Time).
| Tester Display |
|---|
| Stop&Start Operating Prohibition (Manual Start for the First Time) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Prohibition (Manual Start for the First Time) | Prohibition of stop and start control based on the manual start conditions | Permit / Prohibit | Permit: Except for manual start conditions | ·
When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off. ·
During manual start conditions: -
Clutch start switch OFF or vehicle speed signal input -
Neutral position sensor (neutral position switch) OFF -
Starter signal OFF |
| Result | Proceed to |
|---|---|
| Permit is displayed | A |
| Prohibit is displayed | B |
A
B
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
| Tester Display |
|---|
| Battery Type |
Check the "Battery Type" Data List Item.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set auxiliary battery type | Specified / Other | Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery |
- |
Check whether the auxiliary battery is specified or not specified.
| Data List Battery Type Display | Equipped Auxiliary Battery | Proceed to |
|---|---|---|
| Other | Specified auxiliary battery | A |
| Other | Non-specified auxiliary battery | B |
A
B
When switching to a specified auxiliary battery, Auxiliary Battery Type may not immediately switch to "Specified". To immediately switch it to "Specified", perform Switch Auxiliary Battery Type.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Enter the following menus: Powertrain / Engine / Utility / Switch Battery Type.
| Tester Display |
|---|
| Switch Battery Type |
Perform Switch Auxiliary Battery Type under Utility and set the Specified auxiliary battery.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
| Tester Display |
|---|
| Battery Type |
Check that the "Battery Type" Data List item is set to "Specified".
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set auxiliary battery type | Specified / Other | Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery |
- |
| Proceed to |
|---|
| NEXT |
NEXT
Check the operation of the backup boost converter.
Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC.
| Tester Display |
|---|
| State of BBC |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| State of BBC | Backup boost converter status | Cycle Err / Overvoltage / Overload / Normal / Low Vol / Duty Err / Stop&Start Sensor Electric Supply Low / Stop&Start CPU Malfunction / BBC Overcurrent / Stop&Start Starter Overcurrent / Stop&Start Reduced Voltage Reset | Normal: Backup boost converter operating normally | ·
Duty Err: -
Abnormal duty ratio is detected. ·
Cycle Err: -
Abnormal output voltage cycle is detected. ·
Low Vol: -
A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON. ·
Overload: -
Overcurrent is detected. ·
Overvoltage: -
When the ignition switch is ON: (1)
Overvoltage is detected at the control IC power source in the backup boost converter (2)
Overheating is detected at the control IC power source in the backup boost converter -
When boosting: (1)
Malfunction is detected in the feedback circuit in the backup boost converter (2)
Too high or low output voltage. |
| Result | Proceed to |
|---|---|
| Normal is displayed | A |
| Normal is not displayed | B |
A
B
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>Backup Boost Converter Circuit
Check if stop and start control was prohibited due to condition of the generator assembly.
Start the engine.
Check the condition of the charge warning.
| Result | Proceed to |
|---|---|
| Charge warning does not come on when engine running | A |
| Charge warning comes on when engine running | B |
A
B
for 1KR-FE: Click herePower Source / Network>1KR-FE (BATTERY / CHARGING)>CHARGING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
for M15A-FKS: Click herePower Source / Network>M15A-FKS (BATTERY / CHARGING)>CHARGING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
for G16E-GTS: Click herePower Source / Network>G16E-GTS (BATTERY / CHARGING)>CHARGING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Check the idling stop rate.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Fluid Temperature, Idling Stop Rate and Total Idling Stop Rate.
| Tester Display |
|---|
| Battery Fluid Temperature |
| Idling Stop Rate |
| Total Idling Stop Rate |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Fluid Temperature | Estimated temperature inside auxiliary battery | Min.: -40°C (-40°F)
Max.: 215°C (419°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Idling Stop Rate | Rate of the idling stop time to the entire ignition switch to ON time of this trip | Min.: 0%
Max.: 255% |
- | - |
| Total Idling Stop Rate | Rate of the overall idling stop time to the overall ignition switch to ON time | Min.: 0%
Max.: 255% |
- | - |
| Result | Proceed to | |
|---|---|---|
| Total Idling Stop Rate | Idling Stop Rate | |
| 40% or less | - | A |
| - | 50% or less | |
| Other than above | B | |
A
B
If Idling Stop Rate is more than threshold or Total Idling Stop Rate is more than threshold, leave the vehicle with the engine running until Idling Stop Rate drops below threshold or Total Idling Stop Rate drops below threshold.
For details on the Idling Stop Rate and Total Idling Stop Rate thresholds, refer to System Description.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>SYSTEM DESCRIPTION
Prohibition according to the Idling Stop Rate is used to limit a high frequency of stop and start operations in order to ensure the lifespan of the auxiliary battery. Operation may be prohibited again due to the customer usage conditions.
Check the auxiliary battery fluid temperature.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Fluid Temperature and Ambient Temperature.
| Tester Display |
|---|
| Battery Fluid Temperature |
| Ambient Temperature |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Fluid Temperature | Estimated temperature inside auxiliary battery | Min.: -40°C (-40°F)
Max.: 215°C (419°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Ambient Temperature | Ambient temperature | Min.: -40°C (-40°F)
Max.: 215°C (419°F) |
Close to ambient temperature | - |
| Result | Proceed to |
|---|---|
| Both Battery Fluid Temperature and Ambient Temperature are suitable temperature
(Battery Fluid Temperature: -10°C (14°F) or higher and 70°C (158°F) or less, Ambient Temperature: -5°C (23°F) or higher) |
A |
| Battery Fluid Temperature or Ambient Temperature is not suitable temperature
(Battery Fluid Temperature: -15°C (5°F) or less or 75°C (167°F) or higher, Ambient Temperature: -6°C (21.2°F) or less) |
B |
The Battery Fluid Temperature hysteresis is 5°C (9°F) and the Ambient Temperature hysteresis is 1°C (1.8°F).
A
B
If auxiliary battery fluid temperature is not a suitable temperature, leave the vehicle at ambient temperature to allow auxiliary battery fluid temperature to return to a suitable temperature.
Operation is prohibited due to the auxiliary battery fluid temperature to ensure engine startability and protect the auxiliary battery. This occurs due to the usage environment.
Check whether stop and start control was prohibited based on the auxiliary battery charge control mode.
Connect the GTS to the DLC3.
Start the engine and allow it to idle.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.
| Tester Display |
|---|
| Status of Battery Charge Control |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Status of Battery Charge Control | Auxiliary battery charge control status | Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Auxiliary Battery Condition Judgment Mode / Low Temperature Mode | - | - |
| Result | Proceed to |
|---|---|
| "Refresh Charge Mode", "Auxiliary Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed | A |
| "Refresh Charge Mode" is displayed | B |
| "Abnormal Mode" is displayed | C |
| "Auxiliary Battery Condition Judgment Mode" is displayed | D |
A
B
Let the vehicle idle with the auxiliary battery fluid temperature at 11°C (52°F) or higher for 30 to 60 minutes to complete the refresh charge. (The refresh charge is complete when Status of Battery Charge Control changes from "Refresh Charge Mode".)
After the refresh charge completes, turn the ignition switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
C
for 1KR-FE: Click herePower Source / Network>1KR-FE (BATTERY / CHARGING)>CHARGING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
for M15A-FKS: Click herePower Source / Network>M15A-FXE (BATTERY / CHARGING)>CHARGING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
for G16E-GTS: Click herePower Source / Network>G16E-GTS (BATTERY / CHARGING)>CHARGING SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
D
Check whether stop and start control was prohibited based on the minimum starting voltage of the auxiliary battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement) and Stop&Start Operating Permission (Minimum Voltage (Cranking)).
| Tester Display |
|---|
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | Permission of stop and start control based on minimum voltage during starter solenoid engagement | NG / OK | OK: Minimum voltage when starter begins operation is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) | Permission of stop and start control based on minimum voltage during cranking | NG / OK | OK: Minimum voltage when cranking is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
| Result | Proceed to |
|---|---|
| OK is displayed for 2 items | A |
| OK is displayed for 1 item or none | B |
The Data List item "Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) and Stop&Start Operating Permission (Minimum Voltage (Cranking))" is judged OK or NG according to the values of the following Data List items.
| Tester Display |
|---|
| Minimum Voltage (Cranking) |
| Minimum Voltage (Starter Solenoid Engagement) |
| Battery Type |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Minimum Voltage (Cranking) | Minimum voltage when cranking engine | Min.: -327.68 V
Max.: 327.67 V |
6 to 11 V | Lowest auxiliary battery voltage measured after the starter starts operating. |
| Minimum Voltage (Starter Solenoid Engagement) | Minimum voltage when starter begins operation | Min.: -327.68 V
Max.: 327.67 V |
6 to 11 V | Minimum auxiliary battery voltage while the starter starts operating. |
| Battery Type | Set auxiliary battery | Specified / Other | Specified: Specified auxiliary battery
Other: Non-specified auxiliary battery |
- |
| Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
|---|---|---|
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | for Manual Transaxle: 7.2 V or higher for CVT: 7.6 V or higher |
- |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | for Manual Transaxle: 7.2 V or higher for CVT: 8.14 V or higher |
| Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
|---|---|---|
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | 8.92 V or higher | - |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | 8.92 V or higher |
A
B
Check whether stop and start control was prohibited based on the integrated current value auxiliary battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Permission (Integrated Current).
| Tester Display |
|---|
| Stop&Start Operating Permission (Integrated Current) |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Permission (Integrated Current) | Permission of stop and start control based on the integrated current value conditions | NG / OK | OK: Integrated current value is equal to the threshold or more | The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the auxiliary battery fluid temperature. |
| Result | Proceed to |
|---|---|
| OK is displayed | A |
| NG is displayed | B |
A
B
Check the engine hood courtesy switch (hood lock assembly).
Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.
| Tester Display |
|---|
| Hood Courtesy Switch |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hood Courtesy Switch | Hood courtesy switch signal | ON / OFF | ON: Engine hood closed
OFF: Engine hood open |
- |
| Result | Proceed to |
|---|---|
| When engine hood condition changes from open to closed, Data List switches from OFF to ON | A |
| When engine hood condition changes from open to closed, Data List remains OFF | B |
If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.
A
B
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>Engine Hood Courtesy Switch Circuit
Check that the engine hood and back door*1 are closed.
*1: for 3 Door
Turn the ignition switch off and wait for 30 seconds or more.
Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Operating Prohibition (Jump Start).
| Tester Display |
|---|
| Stop&Start Operating Prohibition (Jump Start) |
Check that the Data List item "Stop&Start Operating Prohibition (Jump Start)" displays "Permit".
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop&Start Operating Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start conditions | Permit / Prohibit | Permit: Except for jump start conditions | When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Jump start conditions: Engine started with the engine hood or back door*1 open and the ignition switch turned START |
*1: for 3 Door
| Proceed to |
|---|
| NEXT |
Stop and start control may be prohibited if the engine was started with the engine hood open.
NEXT
Judge the auxiliary battery condition based on the integrated current value.
Connect the GTS to the DLC3.
Start the engine and allow it to idle.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.
| Tester Display |
|---|
| Integrated Current |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Integrated Current | Auxiliary battery integrated current | Min.: -268434.456 Asec
Max.: 268435.4558 Asec |
Differs according to the vehicle condition (charge/discharge conditions) | - |
Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.
| Tester Display |
|---|
| Battery Current |
| Integrated Current |
| Status of Battery Charge Control |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Current | Auxiliary battery current | Min.: -125 A
Max.: 124.9961 A |
- | - |
| Integrated Current | Auxiliary battery integrated current | Min.: -268434.456 Asec
Max.: 268435.4558 Asec |
Differs according to vehicle condition (charge/discharge conditions) | - |
| Status of Battery Charge Control | Auxiliary battery charge control status | Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode | - | - |
| Status of Battery Charge Control | Integrated Current | Proceed to |
|---|---|---|
| Charge Control Coordination Mode, Stop and Start Standalone Mode and Low Temperature Mode | Below -3974 A-sec | A |
| Stop and Start Restriction Mode and Temperature High/Low Mode | Below 0 A-sec | B |
| Result | Cause | Action to be Taken |
|---|---|---|
| A | Integrated current value is limited for the stop and start control due to discharge or deterioration of the auxiliary battery | Check the auxiliary battery condition and recharge the auxiliary battery |
| B | 1.
Electrical load is excessive 2.
Auxiliary battery deterioration 3.
Refresh charging was not completed properly |
1.
Turn electrical load off as much as possible 2.
CHARGE OR REPLACE AUXILIARY BATTERY AFTER CHECKING AUXILIARY BATTERY STATE (refer to procedure 19) 3.
Restart the engine after waiting 30 seconds or more after stopping the engine. If refresh charging begins once more, wait until refresh charging completes while idling. |
Initialize* the auxiliary battery integrated current using the GTS after charging the auxiliary battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).
*: Use the GTS to perform Integrated Current Value Initialization.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
If the Data List item "Integrated Current" is 0 A-sec or higher, it is not necessary to perform initialization.
When the auxiliary battery state sensor assembly current value is normal, recharge or replace the auxiliary battery
When the electrical load is large, a large amount of electrical discharge occurs. As a result, the integrated current value (auxiliary battery charge amount) tends to drop causing operation to be prohibited.
| Proceed to |
|---|
| NEXT |
NEXT
Refer to Integrated Current Value Initialization.
Click here
If the integrated current value does not exceed the threshold*1 even though the auxiliary battery has been replaced or charged until the charging current decreases to 5 A or less, perform an integrated current value initialization*2 and drive the vehicle for approximately 5 to 40 minutes until the stop and start system operates.
*1: Refer to System Description for details on the integrated current threshold.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>SYSTEM DESCRIPTION
*2: Use the GTS to perform Integrated Current Value Initialization.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Check the auxiliary battery.
for 1KR-FE: Click herePower Source / Network>1KR-FE (BATTERY / CHARGING)>CHARGING SYSTEM>ON-VEHICLE INSPECTION
for M15A-FKS: Click herePower Source / Network>M15A-FKS (BATTERY / CHARGING)>CHARGING SYSTEM>ON-VEHICLE INSPECTION
for G16E-GTS: Click herePower Source / Network>G16E-GTS (BATTERY / CHARGING)>CHARGING SYSTEM>ON-VEHICLE INSPECTION
Charge or replace the auxiliary battery according to the check result.
When the cable is disconnected from the auxiliary battery terminal or the charging control system is checked (ECM connector is disconnected), do not perform this procedure, as there is a high possibility that the system may enter refresh charge mode and operation may be prohibited.
Check the starter inrush current reduction relay. (for CVT)
Connect the GTS to the DLC3.
Start the engine.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Current.
| Tester Display |
|---|
| Battery Current |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Current | Auxiliary battery current | Min.: -125 A
Max.: 124.9961 A |
- | - |
While idling, illuminate the headlights (Lo).
The headlights (Lo) are illuminated so that charging control is prohibited, which sets the voltage to a fixed value.
Charge the auxiliary battery for approximately 5 minutes after Auxiliary battery Current drops to 5 A or less.
The Data List item Battery Current decreases when the battery is charged. If the auxiliary battery is charged for 5 minutes after Auxiliary battery Current drops to 5 A or less, it can be determined that the auxiliary battery is sufficiently charged.
Turn off the headlights.
Turn the ignition switch off and wait for 30 seconds or more.
Start the engine and check the following Data List items.
| Tester Display |
|---|
| Minimum Voltage (Cranking) |
| Minimum Voltage (Starter Solenoid Engagement) |
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Minimum Voltage (Cranking) | Minimum voltage when cranking engine | Min.: -327.68 V
Max.: 327.67 V |
6 to 11 V | Lowest auxiliary battery voltage measured after the starter starts operating. |
| Minimum Voltage (Starter Solenoid Engagement) | Minimum voltage when starter begins operation | Min.: -327.68 V
Max.: 327.67 V |
6 to 11 V | Minimum auxiliary battery voltage while the starter starts operating. |
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | Permission of stop and start control based on minimum voltage during starter solenoid engagement | NG / OK | OK: Minimum voltage when starter begins operation is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) | Permission of stop and start control based on minimum voltage during cranking | NG / OK | OK: Minimum voltage when cranking is equal to the threshold or higher | If both Minimum Voltage (Starter Solenoid Engagement) condition and Minimum Voltage (Cranking) condition are OK, stop and start control is permitted. |
| Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
|---|---|---|
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | for Manual Transaxle/Manual Transmission: 7.2 V or higher for CVT: 7.6 V or higher |
- |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | for Manual Transaxle/Manual Transmission: 7.2 V or higher for CVT: 8.14 V or higher |
| Tester Display | Minimum Voltage (Starter Solenoid Engagement) | Minimum Voltage (Cranking) |
|---|---|---|
| Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement)) | 8.92 V or higher | - |
| Stop&Start Operating Permission (Minimum Voltage (Cranking)) | - | 8.92 V or higher |
Replace the auxiliary battery in the following situations.
Stop&Start Operating Permission (Minimum Voltage (Starter Solenoid Engagement), Minimum Voltage(Cranking)) are not OK.
Stop&Start Operating Permission (Minimum Voltage Starter Solenoid Engagement), Minimum Voltage (Cranking)) are OK, but Minimum Voltage (Starter Solenoid Engagement) and Minimum Voltage(Cranking) values are close to permission criteria.
| Proceed to |
|---|
| NEXT |
NEXT
Refer to Integrated Current Value Initialization.
Click here
If the integrated current value does not exceed the threshold*1 even though the auxiliary battery has been replaced or charged until the charging current decreases to 5 A or less, perform an integrated current value initialization*2 and drive the vehicle for approximately 5 to 40 minutes until the stop and start system operates.
*1: Refer to System Description for details on the integrated current threshold.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>SYSTEM DESCRIPTION
*2: Use the GTS to perform Integrated Current Value Initialization.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION