Certification ECU Power Source Circuit
Circuit diagnosis · Vehicles built from Aug 2005
DESCRIPTION
This circuit provides power to operate the certification ECU.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT FUSE (ECU-B) |
Remove the ECU-B fuse from the engine room R/B and J/B.

Measure the resistance.
- Standard resistance:
- Below 1 Ω
Reinstall the ECU-B fuse.
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - BATTERY AND BODY GROUND) |
![]() ![]() |
Disconnect the D60 certification ECU connector.
Measure the resistance and voltage of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
D60-17 (E) - Body ground
Below 1 Ω
- Standard voltage:
Tester Connection
Specified Condition
D60-1 (+B1) - Body ground
11 to 14 V
Reconnect the certification ECU connector.
|
|
||||
| OK | ||
| ||