2005-2008 Yaris · Service Manual STEERING

DATA LIST / ACTIVE TEST

System information · Vehicles built from Aug 2005


DATA LIST
  1. Connect an intelligent tester to the DLC3.

  2. Turn the ignition switch on (IG) and turn the tester on.

  3. Operate the intelligent tester according to the prompts on the tester and select DATA LIST.

Item
Item Description
Inspection Condition
Reference value
Torque Sensor 1 Output
Torque sensor 1 output value:
Minimum: 0 V, Maximum: 5 V
  1. Steering wheel not turned (without load)
  2. Steering wheel turned to right with vehicle stopped
  3. Steering wheel turned to left with vehicle stopped
  1. 2.3 to 2.7 V
  2. 2.5 to 4.7 V
  3. 0.3 to 2.5 V
Torque Sensor 2 Output
Torque sensor 2 output value:
Minimum: 0 V, Maximum: 5 V
  1. Steering wheel not turned (without load)
  2. Steering wheel turned to right with vehicle stopped
  3. Steering wheel turned to left with vehicle stopped
  1. 2.3 to 2.7 V
  2. 2.5 to 4.7 V
  3. 0.3 to 2.5 V
Torque Sensor 3 Output
Torque value for assist control:
Minimum: 0 V, Maximum: 5 V
  1. Steering wheel not turned (without load)
  2. Steering wheel turned to right with vehicle stopped
  3. Steering wheel turned to left with vehicle stopped
  1. 2.3 to 2.7 V
  2. 2.5 to 4.7 V
  3. 0.3 to 2.5 V
Meter Vehicle Velocity
Vehicle speed from meter:
Minimum: 0 km/h (mph), Maximum: 255 km/h (158.5 mph)
  1. Vehicle stopped
  2. Vehicle driven at constant speed
  1. 0 km/h (mph)
  2. No significant fluctuation
Motor Actual Current
Current to motor:
Minimum: -128 A, Maximum: 127 A
-
-
Command Value Current
Requested current to motor:
Minimum: -128 A, Maximum: 127 A
-
-
Thermistor Temperature
ECU substrate temperature:
Minimum: -50 °C, Maximum: 205 °C
Ignition switch on (IG)
-
PIG Power Supply
Power source voltage to activate motor:
Minimum: 0 V, Maximum: 25.5 V
Power steering in operation
10 to 16 V
IG Power Supply
ECU power source voltage:
Minimum: 0 V, Maximum: 25.5 V
-
10 to 16 V
TRQ1 Zero Point Value
Zero point value of torque sensor 1:
Minimum: 0 V, Maximum: 5 V
Steering wheel not turned (without load)
2.3 to 2.7 V
TRQ2 Zero Point Value
Zero point value of torque sensor 2:
Minimum: 0 V, Maximum: 5 V
Steering wheel not turned (without load)
2.3 to 2.7 V
TRQ3 Zero Point Value
Zero point value of torque sensor for assist control:
Minimum: 0 V, Maximum: 5 V
Steering wheel not turned (without load)
2.3 to 2.7 V
Motor Terminal Volt (+)
Motor terminal M1 voltage:
Minimum: 0 V, Maximum: 25.5 V
  1. Steering wheel turned to right
  2. Steering wheel turned to left
  1. Below 1 V (LHD)
    10 to 16 V (RHD)
  2. 10 to 16 V (LHD)
    Below 1 V (RHD)
Motor Terminal Volt (-)
Motor terminal M2 voltage:
Minimum: 0 V, Maximum: 25.5 V
  1. Steering wheel turned to right
  2. Steering wheel turned to left
  1. 10 to 16 V (LHD)
    Below 1 V (RHD)
  2. Below 1 V (LHD)
    10 to 16 V (RHD)
Motor Overheat Record
Continuous overheat prevention control record:
REC/UNREC
-
-
Motor Low Power Record
PIG power source voltage drop record:
REC/UNREC
-
-
Control Mode
Codes indicating DTC detection timing during ECU control displayed in hexadecimal
-
-
IG ON/OFF Times
Number of times ignition switch turned on (IG) after DTC detection:
Minimum: 0 time, Maximum: 255 times
-
-
Number of Trouble Code
Number of detected DTCs when freeze frame data stored:
Minimum: 0 time, Maximum: 255 times
-
-
ECU Identification
ECU identification information
-
-
← FAIL-SAFE CHART (from Jan 2006)DIAGNOSTIC TROUBLE CODE CHART (Aug 2005 – Dec 2005) →