B1830/57 Short in Driver Side Curtain Shield Squib Circuit
Diagnostic trouble codes · Vehicles built from Aug 2005
Also covers:
- B1831/57 Open in Driver Side Curtain Shield Squib Circuit
- B1832/57 Short to GND in Driver Side Curtain Shield Squib Circuit
- B1833/57 Short to B+ in Driver Side Curtain Shield Squib Circuit
DESCRIPTION
The driver side curtain shield squib circuit consists of the center airbag sensor assembly and the driver side curtain shield airbag assembly.The circuit signals the SRS to deploy when deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the driver side curtain shield squib circuit.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1830/57 |
|
|
| B1831/57 |
|
|
| B1832/57 |
|
|
| B1833/57 |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Perform the simulation method by selecting CHECK MODE (signal check) with the intelligent tester (Click here).
- After selecting CHECK MODE (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on a city or rough road (Click here).
- Perform the simulation method by selecting CHECK MODE (signal check) with the intelligent tester (Click here).
| 1. CHECK CURTAIN SHIELD AIRBAG ASSEMBLY LH (DRIVER SIDE CURTAIN SHIELD SQUIB) |
![]() ![]() |
- SST
- 09843-18060
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the driver side curtain shield airbag assembly.
Connect the white wire side of SST (resistance 2.1 Ω) to connector C.
- CAUTION:
- Never connect a tester to the driver side curtain shield airbag assembly for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert the SST into the terminals of the connector when connecting.
- Insert the SST straight into the terminals of the connector.
- Do not forcibly insert the SST into the terminals of the connector when connecting.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832, B1833 and 57 are not output.
- HINT:
- DTCs other than DTC B1830, B1831, B1832, B1833 and 57 may be output at this time, but they are not related to this check.
|
|
||||
|
|
||||
| NG | |
| 2. CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector C.
Check that the floor wire connectors (on the driver side curtain shield airbag assembly side) are not damaged.
- OK:
- The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
|
|
||||
| OK | |
| 3. CHECK FLOOR WIRE (DRIVER SIDE CURTAIN SHIELD SQUIB CIRCUIT) |
![]() ![]() |
Disconnect the connectors from the center airbag sensor assembly.
Check for short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage.
- Standard voltage:
Tester connection
Condition
Specified condition
J23-1 (ICL+) - Body ground (*1)
Ignition switch on (IG)
Below 1 V
J23-2 (ICL-) - Body ground (*1)
Ignition switch on (IG)
Below 1 V
J22-1 (ICR+) - Body ground (*2)
Ignition switch on (IG)
Below 1 V
J22-2 (ICR-) - Body ground (*2)
Ignition switch on (IG)
Below 1 V
Check for open in the circuit.
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance.
- Standard resistance:
Tester connection
Condition
Specified condition
J23-1 (ICL+) - J23-2 (ICL-) (*1)
Always
Below 1 Ω
J22-1 (ICR+) - J22-2 (ICR-) (*2)
Always
Below 1 Ω
Check for short to ground in the circuit.
Measure the resistance.
- Standard resistance:
Tester connection
Condition
Specified condition
J23-1 (ICL+) - Body ground (*1)
Always
1 MΩ or higher
J23-2 (ICL-) Body ground (*1)
Always
1 MΩ or higher
J22-1 (ICR+) - Body ground (*2)
Always
1 MΩ or higher
J22-2 (ICR-) Body ground (*2)
Always
1 MΩ or higher
Check for short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance.
- Standard resistance:
Tester connection
Condition
Specified condition
J23-1 (ICL+) - J23-2 (ICL-) (*1)
Always
1 MΩ or higher
J22-1 (ICR+) - J22-2 (ICR-) (*2)
Always
1 MΩ or higher
|
|
||||
| OK | |
| 4. CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() ![]() |
Connect the connectors to the diver side curtain shield airbag assembly and the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832, B1833 and 57 are not output.
- HINT:
- DTCs other than DTC B1830, B1831, B1832, B1833 and 57 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||