INSPECTION
Inspection · Vehicles built from Nov 2006
| INSPECT CRANKSHAFT POSITION SENSOR |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.

- Standard resistance:
Temperature
Specified Condition
Cold
985 to 1600 Ω
Hot
1265 to 1890 Ω
- HINT:
- In the table above, the terms Cold and Hot refer to the temperature of the coils. Cold means approximately -10 to 50 °C (14 to 122 °F). Hot means approximately 50 to 100 °C (122 to 212 °F).