INSPECTION
Inspection · Vehicles built from Aug 2005
| INSPECT HAZARD WARNING SIGNAL SWITCH |
![]() ![]() |
Check the resistance.
Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 4
OFF
10 kΩ or higher
1 - 4
ON
Below 1 Ω
2 - 3
Illumination circuit
Below 1 Ω
Check the illumination operation.
Connect the positive (+) battery lead to terminal 3 and the negative (-) battery lead to terminal 2, then check that the illumination illuminates.
- Standard:
- Illumination illuminates.