2005-2008 Yaris · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Aug 2005


INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

A092175E01
  1. Using vernier calipers, measure the exposed brush length.

    Standard exposed length:
    9.5 to 11.5 mm (0.374 to 0.453 in.)

    Minimum exposed length:
    1.5 mm (0.059 in.)

    If the exposed length is less than the minimum, replace the generator brush holder assembly.


INSPECT GENERATOR REGULATOR ASSEMBLY

A085101E01
  1. Using an ohmmeter, check the continuity between terminals F and B.

    Standard:
    When the positive and negative poles between terminals F and B are exchanged, there is continuity in one direction but no continuity in the other direction.

    If the continuity is not as specified, replace the generator regulator assembly.

  1. A085102E01
    Using an ohmmeter, check the continuity between terminals F and E.

    Standard:
    When the positive and negative poles between terminals F and E are exchanged, there is continuity in one direction but no continuity in the other direction.

    If the continuity is not as specified, replace the generator regulator assembly.


INSPECT GENERATOR DRIVE END FRAME

A082703E04
  1. Check the stator coil for open circuits.

    1. Using an ohmmeter, check the resistance between the coil leads.

      Standard resistance:
      Below 1 Ω

      If the result is not as specified, replace the generator assembly.

  1. A082704E03
    Inspect the stator for ground.

    1. Using an ohmmeter, check the resistance between the coil lead and drive end frame.

      Standard resistance:
      10 kΩ or higher

      If the result is not as specified, replace the generator assembly.

  1. Inspect the bearing.

    1. Make sure that the bearing is not rough or worn.
      If necessary, replace the generator assembly.


INSPECT GENERATOR HOLDER WITH RECTIFIER

A108392E03
  1. Using an ohmmeter, check the continuity among terminals P1, P2, P3 and B, and among P1, P2, P3 and E.

    Standard:
    When the positive and negative poles among terminals P1, P2, P3 and B are exchanged, there is continuity in one direction but no continuity in the other direction.
    When the positive and negative poles among terminals P1, P2, P3 and E are exchanged, there is continuity in one direction but no continuity in the other direction.

    If the continuity is not as specified, replace the generator holder with rectifier.


INSPECT GENERATOR ROTOR ASSEMBLY

A067421E02
  1. Check the generator rotor for open circuits.

    1. Using an ohmmeter, measure the resistance between the slip rings.

      Standard resistance:
      1.7 to 2.1 Ω at 20°C (68°F)

      If the resistance is not as specified, replace the generator rotor assembly.

  1. A067422E02
    Check the generator rotor for short circuits.

    1. Using an ohmmeter, check the resistance between the slip ring and generator rotor assembly.

      Standard resistance:
      10 kΩ or higher

      If the result is not as specified, replace the generator rotor assembly.

  1. Inspect slip rings.

    1. Make sure that the slip rings are not rough or scored.
      If rough or scored, replace the generator rotor assembly.

    2. A094149E01
      Using vernier calipers, measure the slip ring diameter.

      Standard diameter:
      14.2 to 14.4 mm (0.559 to 0.567 in.)

      Minimum diameter:
      12.8 mm (0.504 in.)

      If the diameter is less than the minimum, replace the generator rotor assembly.

← DISASSEMBLY (from Aug 2005)REASSEMBLY (from Aug 2005) →