B1411/11 Room Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Aug 2005
DESCRIPTION
The room temperature sensor is installed in the instrument panel to detect the room temperature and control the heater and air conditioner AUTO mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier applies a voltage (5V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1411/11 |
Open or short in room temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (ROOM TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Data List / Air Conditioner:
Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Room Temp
Room temperature sensor / Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature is displayed
Open circuit: -6.5°C (20.3°F)
Short circuit: 57.25°C (135.05°F)
- OK:
- The display is as specified in the normal condition column.
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT ROOM TEMPERATURE SENSOR |
![]() ![]() |
Remove the room temperature sensor.
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E12-1 (ST+) - E12-2 (ST-)
10°C (50°F)
3.00 to 3.73 kΩ
E12-1 (ST+) - E12-2 (ST-)
15°C (59°F)
2.45 to 2.88 kΩ
E12-1 (ST+) - E12-2 (ST-)
20°C (68°F)
1.95 to 2.30 kΩ
E12-1 (ST+) - E12-2 (ST-)
25°C (77°F)
1.60 to 1.80 kΩ
E12-1 (ST+) - E12-2 (ST-)
30°C (86°F)
1.28 to 1.47 kΩ
E12-1 (ST+) - E12-2 (ST-)
35°C (95°F)
1.00 to 1.22 kΩ
E12-1 (ST+) - E12-2 (ST-)
40°C (104°F)
0.80 to 1.00 kΩ
E12-1 (ST+) - E12-2 (ST-)
45°C (113°F)
0.65 to 0.85 kΩ
E12-1 (ST+) - E12-2 (ST-)
50°C (122°F)
0.50 to 0.70 kΩ
E12-1 (ST+) - E12-2 (ST-)
55°C (131°F)
0.44 to 0.60 kΩ
E12-1 (ST+) - E12-2 (ST-)
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph on the left).
Reinstall the room temperature sensor.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() ![]() |
Disconnect the E12 room temperature sensor connector.
Disconnect the E11 air conditioning amplifier connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
E12-1 (ST+) - E11-29 (TR)
Below 1Ω
E12-2 (ST-) - E11-34 (SG-1)
Below 1Ω
E12-1 (ST+) - Body ground
1MΩ or higher
E12-2 (ST-) - Body ground
1MΩ or higher
Reconnect the room temperature sensor connector.
Reconnect the air conditioning amplifier connector.
|
|
||||
| OK | ||
| ||