2005-2008 Yaris · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1412/12 Ambient Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built from Aug 2005

DESCRIPTION

The ambient temperature sensor is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner. The sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier via the combination meter. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the ambient temperature sensor and reads voltage changes as changes in the resistance of the ambient temperature sensor. The combination meter sends the read signal to the air conditioning amplifier via CAN communications.
DTC No.
DTC Detection Condition
Trouble Area
B1412/12
Open or short in ambient temperature sensor circuit
  1. Ambient temperature sensor
  2. Harness and connector between ambient temperature sensor and combination meter assembly
  3. Combination meter assembly
  4. Air conditioning amplifier
  5. CAN communication line

WIRING DIAGRAM

E115798E03

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (AMBI TEMP SENS)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the value displayed on the intelligent tester.

    Data List / Air Conditioner:
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Ambi Temp Sens
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    Open circuit: -23.3°C (-9.94°F)
    Short circuit: 65.95°C (150.71°F)

    OK:
    The display is as specified in the normal condition column.


    Result:
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2. INSPECT AMBIENT TEMPERATURE SENSOR
E114516E02
  1. Remove the ambient temperature sensor.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B5-1 - B5-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    B5-1 - B5-2
    15°C (50°F)
    2.45 to 2.88 kΩ
    B5-1 - B5-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    B5-1 - B5-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    B5-1 - B5-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    B5-1 - B5-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    B5-1 - B5-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    B5-1 - B5-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    B5-1 - B5-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    B5-1 - B5-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    B5-1 - B5-2
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph on the left).

  1. Reinstall the ambient temperature sensor.



NG
REPLACE AMBIENT TEMPERATURE SENSOR
OK


3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - COMBINATION METER)
E120284E01
  1. Disconnect the B5 ambient temperature sensor connector.

  1. Disconnect the D1 combination meter assembly connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    B5-2 - D1-4 (TEMP)
    Below 1 Ω
    B5-1 - D1-23 (TX1+)
    Below 1 Ω
    B5-2 - Body ground
    1MΩ or higher
    B5-1 - Body ground
    1MΩ or higher

  1. Reconnect the ambient temperature sensor connector.

  1. Reconnect the combination meter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY


← B1411/11 Room Temperature Sensor Circuit (from Aug 2005)B1413/13 Evaporator Temperature Sensor Circuit (from Aug 2005) →