B1412/12 Ambient Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Aug 2005
DESCRIPTION
The ambient temperature sensor is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner. The sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier via the combination meter. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier applies a voltage (5 V) to the ambient temperature sensor and reads voltage changes as changes in the resistance of the ambient temperature sensor. The combination meter sends the read signal to the air conditioning amplifier via CAN communications.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1412/12 |
Open or short in ambient temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AMBI TEMP SENS) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Data List / Air Conditioner:
Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Ambi Temp Sens
Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature is displayed
Open circuit: -23.3°C (-9.94°F)
Short circuit: 65.95°C (150.71°F)
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT AMBIENT TEMPERATURE SENSOR |
![]() ![]() |
Remove the ambient temperature sensor.
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
B5-1 - B5-2
10°C (50°F)
3.00 to 3.73 kΩ
B5-1 - B5-2
15°C (50°F)
2.45 to 2.88 kΩ
B5-1 - B5-2
20°C (68°F)
1.95 to 2.30 kΩ
B5-1 - B5-2
25°C (77°F)
1.60 to 1.80 kΩ
B5-1 - B5-2
30°C (86°F)
1.28 to 1.47 kΩ
B5-1 - B5-2
35°C (95°F)
1.00 to 1.22 kΩ
B5-1 - B5-2
40°C (104°F)
0.80 to 1.00 kΩ
B5-1 - B5-2
45°C (113°F)
0.65 to 0.85 kΩ
B5-1 - B5-2
50°C (122°F)
0.50 to 0.70 kΩ
B5-1 - B5-2
55°C (131°F)
0.44 to 0.60 kΩ
B5-1 - B5-2
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph on the left).
Reinstall the ambient temperature sensor.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - COMBINATION METER) |
![]() ![]() |
Disconnect the B5 ambient temperature sensor connector.
Disconnect the D1 combination meter assembly connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
B5-2 - D1-4 (TEMP)
Below 1 Ω
B5-1 - D1-23 (TX1+)
Below 1 Ω
B5-2 - Body ground
1MΩ or higher
B5-1 - Body ground
1MΩ or higher
Reconnect the ambient temperature sensor connector.
Reconnect the combination meter assembly connector.
|
|
||||
| OK | ||
| ||


