2005-2008 Yaris · Service Manual HEATER & AIR CONDITIONING SYSTEM

DATA LIST / ACTIVE TEST

System information · Vehicles built from Aug 2005


READ DATA LIST
A107926E01

HINT:
Using an intelligent tester's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.

  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch on (IG) and turn the intelligent tester ON.

  3. Read the Data List by following the prompts on the tester.

    DATA LIST 
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Room Temp
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (126.95°F)
    Actual room temperature is displayed
    -
    Ambi Temp Sens
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    -
    Solar Sens-D
    Driver side solar sensor /
    Min.: 0, Max.: 255
    Driver side temperature increases as brightness increases
    -
    Coolant Temp
    Engine coolant temperature /
    Min.: 1.3°C (34.34°F)
    Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature is displayed after engine warmed up
    -
    Set Temp-D
    Driver side set temperature /
    Min.: 0°C (32°F)
    Max.: 30°C (54°F)
    Driver side actual set temperature is displayed
    -
    Estimate Temp-D
    Driver side estimated temperature /
    Min.: -358.4°C (-613.12°F)
    Max.: 358.4°C (677.12°F)
    Driver side estimated temperature is displayed
    -
    Blower Level
    Blower motor speed level /
    Min.: 0 level, Max.: 31 level
    Increases 0 to 31 as blower motor speed increases
    -
    Ambi Temp
    Adjusted ambient temperature /
    Min.: -30.8°C (-23.44°F)
    Max.: 50.8°C (123.44°F)
    -
    -
    Air Mix Pulse-D
    Driver side air mix servo motor target pulse /
    Min.: 0, Max.: 255
    Customized value displayed
    -
    Air Out Pulse-D
    Driver side air outlet servo motor target /
    Min.: 0, Max.: 255
    Customized value displayed
    -
    A/I Damp Targ Pls
    Air inlet damper target pulse /
    Min.: 0, Max.: 255
    Customized value displayed
    -
    Evap Fin Temp
    Evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature is displayed
    -
    Reg Press Sens
    Regulator pressure sensor /
    Min.: 0 kgf/cm2G
    Max.: 38.25 kgf/cm2G
    Actual regulator pressure is displayed
    -
    Reg Ctrl Currnt
    Regulator control current /
    Min.: 0 A
    Max.: 0.997 A
    -
    -
    Air Inlet Mode
    Air inlet mode /
    AUTO, MANUAL
    Customized value displayed
    -
    Compressor Mode
    Compressor mode /
    AUTO, MANUAL
    Customized value displayed
    -
    Comprs / DEF Oper
    Compressor / DEF Mode /
    LINK, NORMAL
    Customized value displayed
    -
    Evap Ctrl
    Evaporator Control /
    AUTO, MANUAL
    Customized value displayed
    -
    Auto Blow Up
    Foot / DEF automatic blow up function /
    ON, OFF
    Customized value displayed
    -
    Foot / DEF Mode
    Foot / DEF auto mode /
    ON, OFF
    Customized value displayed
    -
    Ambient Tmp Sft
    Ambient temperature shift / +3 C, +2 C, +1 C,
    NORMAL, -1 C, -2 C, -3 C
    Customized value displayed
    -
    Set Temp Shift
    Shift set temperature / +2 C, +1 C,
    NORMAL, -1 C, -2 C
    Customized value displayed
    -
    Destination
    Destination / DOMEST, USA, EUROPE, AUSTRAL, MIDEAST, NO INFO
    Destinations displayed
    -
    Number of Trouble Codes
    Number of trouble codes /
    Min.: 0, Max.: 255
    Number of DTCs displayed
    -


PERFORM ACTIVE TEST

HINT:
Performing the intelligent tester's Active Test allows relays, the VSV, actuators and other items to be operated without removing any parts. Performing the Active Test early in troubleshooting is one way to save time. The Data List can be displayed in the Active Test.

  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch on (IG) and turn the intelligent tester ON.

  3. Perform the Active Test by following the prompts on the tester.

    ACTIVE TEST 
    Item
    Test Details / Display (Range)
    Diagnostic Note
    Blower Motor
    Blower motor /
    Min.: 0, Max.: 31
    -
    Heater Level
    PTC Heater relay /
    Min.: 0, Max.: 3
    Perform Active Test with engine running
    A/C Mag Clutch
    A/C Compressor /
    OFF, ON
    -
    Defogger Rly-R
    Defogger relay (Rear) /
    OFF, ON
    -
    Air Mix Pulse-D
    Air mix servo motor pulse (D side) /
    Min.: 0, Max.: 255
    Perform Active Test when value between 4 and 93 displayed
    Air Out Pulse-D
    Air outlet servo motor pulse (D side) /
    Min.: 0, Max.: 255
    Perform Active Test when value between 9 and 101 displayed
    A/I Damp Pulse
    Air inlet damper target pulse /
    Min.: 0, Max.: 255
    Perform Active Test when value between 6 and 22 displayed