DATA LIST / ACTIVE TEST
System information · Vehicles built from Aug 2005
| READ DATA LIST |
![]() ![]() |
- HINT:
- Using an intelligent tester's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester ON.
Read the Data List by following the prompts on the tester.
DATA LIST Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Room Temp
Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (126.95°F)
Actual room temperature is displayed
-
Ambi Temp Sens
Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature is displayed
-
Solar Sens-D
Driver side solar sensor /
Min.: 0, Max.: 255
Driver side temperature increases as brightness increases
-
Coolant Temp
Engine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature is displayed after engine warmed up
-
Set Temp-D
Driver side set temperature /
Min.: 0°C (32°F)
Max.: 30°C (54°F)
Driver side actual set temperature is displayed
-
Estimate Temp-D
Driver side estimated temperature /
Min.: -358.4°C (-613.12°F)
Max.: 358.4°C (677.12°F)
Driver side estimated temperature is displayed
-
Blower Level
Blower motor speed level /
Min.: 0 level, Max.: 31 level
Increases 0 to 31 as blower motor speed increases
-
Ambi Temp
Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
-
-
Air Mix Pulse-D
Driver side air mix servo motor target pulse /
Min.: 0, Max.: 255
Customized value displayed
-
Air Out Pulse-D
Driver side air outlet servo motor target /
Min.: 0, Max.: 255
Customized value displayed
-
A/I Damp Targ Pls
Air inlet damper target pulse /
Min.: 0, Max.: 255
Customized value displayed
-
Evap Fin Temp
Evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature is displayed
-
Reg Press Sens
Regulator pressure sensor /
Min.: 0 kgf/cm2G
Max.: 38.25 kgf/cm2G
Actual regulator pressure is displayed
-
Reg Ctrl Currnt
Regulator control current /
Min.: 0 A
Max.: 0.997 A
-
-
Air Inlet Mode
Air inlet mode /
AUTO, MANUAL
Customized value displayed
-
Compressor Mode
Compressor mode /
AUTO, MANUAL
Customized value displayed
-
Comprs / DEF Oper
Compressor / DEF Mode /
LINK, NORMAL
Customized value displayed
-
Evap Ctrl
Evaporator Control /
AUTO, MANUAL
Customized value displayed
-
Auto Blow Up
Foot / DEF automatic blow up function /
ON, OFF
Customized value displayed
-
Foot / DEF Mode
Foot / DEF auto mode /
ON, OFF
Customized value displayed
-
Ambient Tmp Sft
Ambient temperature shift / +3 C, +2 C, +1 C,
NORMAL, -1 C, -2 C, -3 C
Customized value displayed
-
Set Temp Shift
Shift set temperature / +2 C, +1 C,
NORMAL, -1 C, -2 C
Customized value displayed
-
Destination
Destination / DOMEST, USA, EUROPE, AUSTRAL, MIDEAST, NO INFO
Destinations displayed
-
Number of Trouble Codes
Number of trouble codes /
Min.: 0, Max.: 255
Number of DTCs displayed
-
| PERFORM ACTIVE TEST |
- HINT:
- Performing the intelligent tester's Active Test allows relays, the VSV, actuators and other items to be operated without removing any parts. Performing the Active Test early in troubleshooting is one way to save time. The Data List can be displayed in the Active Test.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester ON.
Perform the Active Test by following the prompts on the tester.
ACTIVE TEST Item
Test Details / Display (Range)
Diagnostic Note
Blower Motor
Blower motor /
Min.: 0, Max.: 31
-
Heater Level
PTC Heater relay /
Min.: 0, Max.: 3
Perform Active Test with engine running
A/C Mag Clutch
A/C Compressor /
OFF, ON
-
Defogger Rly-R
Defogger relay (Rear) /
OFF, ON
-
Air Mix Pulse-D
Air mix servo motor pulse (D side) /
Min.: 0, Max.: 255
Perform Active Test when value between 4 and 93 displayed
Air Out Pulse-D
Air outlet servo motor pulse (D side) /
Min.: 0, Max.: 255
Perform Active Test when value between 9 and 101 displayed
A/I Damp Pulse
Air inlet damper target pulse /
Min.: 0, Max.: 255
Perform Active Test when value between 6 and 22 displayed

