Air Conditioning Control Panel does not Operate
Circuit diagnosis · Vehicles built from Aug 2005
DESCRIPTION
This circuit consists of the air conditioning control assembly and the air conditioning amplifier. When the air conditioning control assembly is operated, signals are transmitted to the air conditioning amplifier through the LIN communication system.If the LIN communication system malfunctions, the air conditioning amplifier does not operate even if the air conditioning control assembly is operated.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND) |
![]() ![]() |
Disconnect the air conditioning control assembly connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
E16-2 (GND) - Body ground
Below 1 Ω
Reconnect the air conditioning control assembly connector.
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - IG CIRCUIT) |
![]() ![]() |
Disconnect the E16 air conditioning control assembly connector.
Measure the voltage.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E16-2 (GND) - E16-5 (IG+)
Ignition Switch on (IG)
10 to 14 V
Reconnect the air conditioning control assembly connector.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR CONDITIONING CONTROL) |
![]() ![]() |
Disconnect the E16 air conditioning control assembly connector.
Disconnect the E11 air conditioning amplifier connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
E11-37 (LIN1) - E16-3 (LIN1)
Below 1 Ω
Reconnect the air conditioning control assembly connector.
Reconnect the air conditioning amplifier connector.
|
|
||||
| OK | |
| 4. REPLACE AIR CONDITIONING CONTROL ASSEMBLY |
Replace the air conditioning control assembly with a new or properly functioning one.
Operate the air conditioning control assembly to check that it functions properly.
- Result:
Result
Proceed to
Air conditioning control assembly malfunctions
A
Air conditioning control assembly functions properly
B
|
|
||||
| A | ||
| ||