INSPECTION
Inspection · Vehicles built from Nov 2005
| INSPECT INJECTION OR SUPPLY PUMP ASSEMBLY |
![]() ![]() |
Check the resistance of the fuel metering unit.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
2.60 to 3.15 Ω at 20°C (68°F)
Check the resistance of the fuel temperature sensor.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
13.92 to 17.01 Ω at -20°C (-4°F)
1 - 2
5.31 to 6.49 Ω at 0°C (32°F)
1 - 2
2.25 to 2.75 Ω at 20 °C (68°F)
1 - 2
1.06 to 1.29 Ω at 40°C (104°F)
1 - 2
0.54 to 0.66 Ω at 60°C (140°F)
1 - 2
0.29 to 0.36 Ω at 80 °C (176°F)
1 - 2
0.17 to 0.20 Ω at 100°C (212°F)